Energy Recovery at Break Pressure Tanks of Gravity Water Supply Lines: A Techno-Economic and Water-Quality Appraisal (Edremit, Türkiye)

Gravity-fed water supply lines dissipate surplus head at break pressure tanks (BPTs), which, unlike pressure reducing valves, have not been appraised as a distinct micro-hydropower siting class. We develop a transferable framework—flow-duration scenarios, least-cost routing of grid connections weighted by 26 transmission experts, a vendor-quoted life-cycle cash flow appraisal valued with measured bills, and a water-quality risk assessment—and apply it to the Edremit line (Türkiye), where five BPTs offer 798 kW and 5.83 GWh in a typical year. The routes deviate only 7.4% from straight lines, whatever the weighting method. As the receiving pumping station consumes only 2.1–2.6 GWh/yr, about half of the output displaces purchases at 7.0 c€/kWh and the rest earns 3.7 c€/kWh; three stations remain viable at a 7% discount rate (internal rate of return 11.4–14.7%), and a fourth only with wider netting. Feasibility is set by the grid connection per kilowatt, not by the turbine: BPT-1, with 15.91 km of line for 35 kW, never recovers its capital. Applied to 84 municipal sites (25.5 MW), this break-even rule separates economically developable from technical potential. Water quality is protected by design: the retrofit adds no pressure boundary, storage or residence time.

Authors

Institutions

Publication Details

Journal
Water
Published
2026-11-16
DOI
https://doi.org/10.3390/w18222864
Primary Topic
Water Systems and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Energy Recovery at Break Pressure Tanks of Gravity Water Supply Lines: A Techno-Economic and Water-Quality Appraisal (Edremit, Türkiye)

Burak Colak, Serhat Küçükali
Water
Water Systems and Optimization
article

Energy Recovery at Break Pressure Tanks of Gravity Water Supply Lines: A Techno-Economic and Water-Quality Appraisal (Edremit, Türkiye)

Burak Colak, Serhat Küçükali
article en

Abstract

Gravity-fed water supply lines dissipate surplus head at break pressure tanks (BPTs), which, unlike pressure reducing valves, have not been appraised as a distinct micro-hydropower siting class. We develop a transferable framework—flow-duration scenarios, least-cost routing of grid connections weighted by 26 transmission experts, a vendor-quoted life-cycle cash flow appraisal valued with measured bills, and a water-quality risk assessment—and apply it to the Edremit line (Türkiye), where five BPTs offer 798 kW and 5.83 GWh in a typical year. The routes deviate only 7.4% from straight lines, whatever the weighting method. As the receiving pumping station consumes only 2.1–2.6 GWh/yr, about half of the output displaces purchases at 7.0 c€/kWh and the rest earns 3.7 c€/kWh; three stations remain viable at a 7% discount rate (internal rate of return 11.4–14.7%), and a fourth only with wider netting. Feasibility is set by the grid connection per kilowatt, not by the turbine: BPT-1, with 15.91 km of line for 35 kW, never recovers its capital. Applied to 84 municipal sites (25.5 MW), this break-even rule separates economically developable from technical potential. Water quality is protected by design: the retrofit adds no pressure boundary, storage or residence time.

WaterVol. 18(22)
Hacettepe University (TR)
Industry, innovation and infrastructure, Affordable and clean energy, Clean water and sanitation
Water Systems and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon