Continuous Glucose Monitoring– Measured Glucose Levels During Oral Glucose Tolerance Testing in Youths With Obesity: Accuracy and Clinical Implications

OBJECTIVE: This study aimed to evaluate the accuracy of continuous glucose monitoring (CGM)-derived glucose values versus venous plasma glucose values during oral glucose tolerance testing (OGTT) in youths with obesity, their effect on glycemic classification, and whether deconvolution-based reconstruction improves agreement. RESEARCH DESIGN AND METHODS: Twenty-nine youths with obesity underwent OGTT while wearing a FreeStyle Libre 2 sensor. Raw CGM values were temporally aligned with venous plasma glucose values and used to reconstruct plasma profiles via a first-order plasma-interstitial kinetic model and inverse filtering. Accuracy, agreement, consensus error grid, and glycemic classification were compared with collected venous plasma glucose values. RESULTS: Temporally aligned CGM-derived values showed limited agreement with collected venous plasma glucose values (mean absolute relative difference [MARD] 12.96%; 51.72% of values within ±10 mg/dL; 20.06% of values differing by >25 mg/dL) and caused classification shifts. After reconstruction, MARD decreased to 5.55%, the proportion of values within ±10 mg/dL increased to 75.86%, almost all values fell within consensus error grid zone A, and classification shifts were reduced. CONCLUSIONS: Deconvolution-based CGM reconstruction may support plasma-referenced, less invasive OGTT-based dysglycemic assessment.

Authors

Institutions

Publication Details

Journal
Diabetes Care
Published
2026-11-16
DOI
https://doi.org/10.2337/dc26-1717
Primary Topic
Diabetes Management and Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Continuous Glucose Monitoring– Measured Glucose Levels During Oral Glucose Tolerance Testing in Youths With Obesity: Accuracy and Clinical Implications

Claudia Anita Piona, Claudio Maffeis, Giuseppe Riccardi, Eleonora M. Aiello et al.
3 links
Diabetes Care
Diabetes Management and Research
article

Continuous Glucose Monitoring– Measured Glucose Levels During Oral Glucose Tolerance Testing in Youths With Obesity: Accuracy and Clinical Implications

Claudia Anita Piona, Claudio Maffeis, Giuseppe Riccardi, Eleonora M. Aiello, Elisa Morotti, Erika Caiazza, Antonella Soglia, Aditya Ravi
article en

Abstract

OBJECTIVE: This study aimed to evaluate the accuracy of continuous glucose monitoring (CGM)-derived glucose values versus venous plasma glucose values during oral glucose tolerance testing (OGTT) in youths with obesity, their effect on glycemic classification, and whether deconvolution-based reconstruction improves agreement. RESEARCH DESIGN AND METHODS: Twenty-nine youths with obesity underwent OGTT while wearing a FreeStyle Libre 2 sensor. Raw CGM values were temporally aligned with venous plasma glucose values and used to reconstruct plasma profiles via a first-order plasma-interstitial kinetic model and inverse filtering. Accuracy, agreement, consensus error grid, and glycemic classification were compared with collected venous plasma glucose values. RESULTS: Temporally aligned CGM-derived values showed limited agreement with collected venous plasma glucose values (mean absolute relative difference [MARD] 12.96%; 51.72% of values within ±10 mg/dL; 20.06% of values differing by >25 mg/dL) and caused classification shifts. After reconstruction, MARD decreased to 5.55%, the proportion of values within ±10 mg/dL increased to 75.86%, almost all values fell within consensus error grid zone A, and classification shifts were reduced. CONCLUSIONS: Deconvolution-based CGM reconstruction may support plasma-referenced, less invasive OGTT-based dysglycemic assessment.

Diabetes Care
University of Verona (IT), University of Trento (IT), University of Pavia (IT), Azienda Ospedaliera Universitaria Integrata Verona (IT)
European Research Executive Agency
Good health and well-being
Diabetes Management and Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon