Performance assessment of thermally sprayed Inconel 625 coatings as an alternative for next-generation central tower solar receivers

This study evaluates thermally sprayed Inconel 625 coatings as an alternative to Pyromark 2500 for solar receivers in Concentrated Solar Power (CSP) systems, particularly Generation 3 (GEN3) plants operating at 800 °C. Inconel 625 coatings were deposited using compact plasma spraying and subjected to thermal pre-treatments (8 h and 168 h at 800 °C). Accelerated thermal cycling (10 000 cycles at 750 °C) was conducted to simulate long-term operating conditions. Solar absorptivity, thermal emissivity, microstructural evolution and coating integrity were assessed. Economic performance was evaluated through Levelized Cost of Coating (LCOC) and Levelized Cost of Energy (LCOE) analyses. The results show that thermally treated Inconel 625 coatings maintain high solar absorptivity (∼93%) after extensive thermal cycling, independently of the initial condition, while exhibiting lower emissivity (70–86%) than Pyromark (83–96%). X-ray diffraction and electron microscopy analyses revealed the formation of stable Cr 2 O 3 , NiO and spinel oxides, which were associated with the stabilization of optical properties and the preservation of coating integrity. No coating delamination was observed after 10 000 cycles, demonstrating excellent thermo-mechanical compatibility with the substrate. At 800 °C, Inconel 625 coatings exhibited superior durability and lower LCOE values (45.89–46.48 USD/MWh) than Pyromark (48.78 USD/MWh). While Pyromark remains more cost-effective for GEN2 plants operating at 540 °C, thermally pre-treated Inconel 625 coatings represent a robust alternative for GEN3 receivers due to their superior thermal stability, optical durability and reduced maintenance requirements. These findings highlight the potential of thermally sprayed Inconel 625 coatings for next-generation high-temperature solar receiver applications.

Authors

Institutions

Publication Details

Journal
Solar Energy Materials and Solar Cells
Published
2026-11-16
DOI
https://doi.org/10.1016/j.solmat.2026.114835
Primary Topic
Solar Thermal and Photovoltaic Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Performance assessment of thermally sprayed Inconel 625 coatings as an alternative for next-generation central tower solar receivers

Claudio J. Múnez, Pedro Poza, David Merino-Millán, N. Martínez
2 links
Solar Energy Materials and Solar Cells
Solar Thermal and Photovoltaic Systems
article

Performance assessment of thermally sprayed Inconel 625 coatings as an alternative for next-generation central tower solar receivers

Claudio J. Múnez, Pedro Poza, David Merino-Millán, N. Martínez
article en

Abstract

This study evaluates thermally sprayed Inconel 625 coatings as an alternative to Pyromark 2500 for solar receivers in Concentrated Solar Power (CSP) systems, particularly Generation 3 (GEN3) plants operating at 800 °C. Inconel 625 coatings were deposited using compact plasma spraying and subjected to thermal pre-treatments (8 h and 168 h at 800 °C). Accelerated thermal cycling (10 000 cycles at 750 °C) was conducted to simulate long-term operating conditions. Solar absorptivity, thermal emissivity, microstructural evolution and coating integrity were assessed. Economic performance was evaluated through Levelized Cost of Coating (LCOC) and Levelized Cost of Energy (LCOE) analyses. The results show that thermally treated Inconel 625 coatings maintain high solar absorptivity (∼93%) after extensive thermal cycling, independently of the initial condition, while exhibiting lower emissivity (70–86%) than Pyromark (83–96%). X-ray diffraction and electron microscopy analyses revealed the formation of stable Cr 2 O 3 , NiO and spinel oxides, which were associated with the stabilization of optical properties and the preservation of coating integrity. No coating delamination was observed after 10 000 cycles, demonstrating excellent thermo-mechanical compatibility with the substrate. At 800 °C, Inconel 625 coatings exhibited superior durability and lower LCOE values (45.89–46.48 USD/MWh) than Pyromark (48.78 USD/MWh). While Pyromark remains more cost-effective for GEN2 plants operating at 540 °C, thermally pre-treated Inconel 625 coatings represent a robust alternative for GEN3 receivers due to their superior thermal stability, optical durability and reduced maintenance requirements. These findings highlight the potential of thermally sprayed Inconel 625 coatings for next-generation high-temperature solar receiver applications.

Solar Energy Materials and Solar CellsVol. 310
Universidad Rey Juan Carlos (ES), Abengoa (Spain) (ES)
Comunidad de Madrid, Agencia Estatal de Investigación
Affordable and clean energy, Climate action
Solar Thermal and Photovoltaic Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon