AIRMESHZ: A ZigBee-Orchestrated Edge-AI Mesh for Adaptive Indoor Air Quality Management and Emergency Ventilation in University Laboratories

University engineering laboratories frequently handle solvents, soldering fumes, and particulate-generating processes that degrade indoor air quality (IAQ). Commercial monitors are typically stand-alone units without coordinated ventilation response, and building management systems rely on scheduled ventilation rather than demand-based control. This paper proposes AIRMESHZ, ZigBee-powered edge-artificial-intelligence mesh that includes a low-cost multi sensor nodes with Convolutional Neural Network (CNN) interference connected on a Raspberry Pi, servo-actuated damper control, and proportional-integral-derivative-regulated exhaust ventilation, combining together to create a powerful mesh that protects students who are performing experiments in an engineering laboratory. Results showed a mean ZigBee coordination latency of 1.86 s, a peak carbon-dioxide abatement of 31.42 percent relative to fixed-schedule ventilation, a damper actuator response of 0.42 s, and a 99.10 percent mesh message-delivery ratio. A comparative analysis of six wireless technologies showed that ZigBee offers the best balance of range, power, mesh support, and latency for multi-node IAQ applications. The paper concludes that multi-node edge-artificial-intelligence coordination over ZigBee is a credible missing layer in current indoor air quality research.

Authors

Publication Details

Journal
Figshare
Published
2026-11-16
DOI
https://doi.org/10.6084/m9.figshare.35025241
Primary Topic
Wireless Sensor Networks and IoT
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

AIRMESHZ: A ZigBee-Orchestrated Edge-AI Mesh for Adaptive Indoor Air Quality Management and Emergency Ventilation in University Laboratories

Lester Niduelan
Figshare
Wireless Sensor Networks and IoT
preprint

AIRMESHZ: A ZigBee-Orchestrated Edge-AI Mesh for Adaptive Indoor Air Quality Management and Emergency Ventilation in University Laboratories

Lester Niduelan
preprint en

Abstract

University engineering laboratories frequently handle solvents, soldering fumes, and particulate-generating processes that degrade indoor air quality (IAQ). Commercial monitors are typically stand-alone units without coordinated ventilation response, and building management systems rely on scheduled ventilation rather than demand-based control. This paper proposes AIRMESHZ, ZigBee-powered edge-artificial-intelligence mesh that includes a low-cost multi sensor nodes with Convolutional Neural Network (CNN) interference connected on a Raspberry Pi, servo-actuated damper control, and proportional-integral-derivative-regulated exhaust ventilation, combining together to create a powerful mesh that protects students who are performing experiments in an engineering laboratory. Results showed a mean ZigBee coordination latency of 1.86 s, a peak carbon-dioxide abatement of 31.42 percent relative to fixed-schedule ventilation, a damper actuator response of 0.42 s, and a 99.10 percent mesh message-delivery ratio. A comparative analysis of six wireless technologies showed that ZigBee offers the best balance of range, power, mesh support, and latency for multi-node IAQ applications. The paper concludes that multi-node edge-artificial-intelligence coordination over ZigBee is a credible missing layer in current indoor air quality research.

Figshare
Industry, innovation and infrastructure
Wireless Sensor Networks and IoT
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon