Silent Articulation from Neck and Submental EMG: the Temporal Fingerprint as the Main Limit of Wearable Recognition

We describe a prototype of a wearable silent speech interface in the form of a necklace. The prototype records surface electromyography (EMG) from the neck and the submental area and recognises words mouthed without sound. The dataset contains 319 trials from one speaker over three days: 8 words and a "silence" class. Within a recording session the model distinguishes 5 words with 76% accuracy (chance 20%) and 3 words with 88% accuracy. We show that the signal carries a fingerprint of the recording time. The day of recording is identified from a single "silence" trial in 100% of cases. Within a day, two series of the same word recorded 6–19 minutes apart are told apart in 85–100% of cases. When tested on a series recorded at another time, accuracy drops to 21–41% on 5 words, and to chance on another day. Conclusion: the main limit of wearable recognition is signal drift over time. It is addressed by calibration when the device is put on and by recording words in random order. Russian and English versions attached. The author is the founder of VOIZEX. Data processing and draft text were prepared with the assistance of Claude (Anthropic); the author reviewed the text and is responsible for it.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-16
DOI
https://doi.org/10.5281/zenodo.24279761
Primary Topic
Muscle activation and electromyography studies
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Silent Articulation from Neck and Submental EMG: the Temporal Fingerprint as the Main Limit of Wearable Recognition

Fedotova Ann
5 links
Zenodo (CERN European Organization for Nuclear Research)
Muscle activation and electromyography studies
preprint

Silent Articulation from Neck and Submental EMG: the Temporal Fingerprint as the Main Limit of Wearable Recognition

Fedotova Ann
preprint en

Abstract

We describe a prototype of a wearable silent speech interface in the form of a necklace. The prototype records surface electromyography (EMG) from the neck and the submental area and recognises words mouthed without sound. The dataset contains 319 trials from one speaker over three days: 8 words and a "silence" class. Within a recording session the model distinguishes 5 words with 76% accuracy (chance 20%) and 3 words with 88% accuracy. We show that the signal carries a fingerprint of the recording time. The day of recording is identified from a single "silence" trial in 100% of cases. Within a day, two series of the same word recorded 6–19 minutes apart are told apart in 85–100% of cases. When tested on a series recorded at another time, accuracy drops to 21–41% on 5 words, and to chance on another day. Conclusion: the main limit of wearable recognition is signal drift over time. It is addressed by calibration when the device is put on and by recording words in random order. Russian and English versions attached. The author is the founder of VOIZEX. Data processing and draft text were prepared with the assistance of Claude (Anthropic); the author reviewed the text and is responsible for it.

Zenodo (CERN European Organization for Nuclear Research)
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon