Six Virgo Spirals: Expected Atomic Mass, Measured Deficiency and the Cluster's Total Take

Deficiency is the bookkeeping unit of cluster gas loss: how much atomic hydrogen a spiral holds, against how much a field twin of the same size would hold. Six Virgo spirals with solid measurements let the cluster's total take be summed, not just sampled. The expected atomic mass follows the diameter calibration for undisturbed late-type galaxies. Deficiency is the logarithm of expected over observed. Stripped mass is the difference of the two, and summing over the six systems gives the sample's total removed atomic mass and its mass-weighted mean deficiency. Headline values are hidef systems count hidef = 6; hidef calibration intercept hidef = 7.3; hidef calibration slope hidef = 1.55; hidef sample expected atomic mass 1e9 msun hidef = 28.59; hidef sample observed atomic mass 1e9 msun hidef = 6.95; hidef sample stripped atomic mass 1e9 msun hidef = 21.64. The sample retained fraction near a quarter is the headline, because it is immune to the calibration scatter that softens each individual deficiency.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-16
DOI
https://doi.org/10.5281/zenodo.24283583
Primary Topic
Galaxies: Formation, Evolution, Phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Six Virgo Spirals: Expected Atomic Mass, Measured Deficiency and the Cluster's Total Take

William Alexander Aldred
1 links
Zenodo (CERN European Organization for Nuclear Research)
Galaxies: Formation, Evolution, Phenomena
article

Six Virgo Spirals: Expected Atomic Mass, Measured Deficiency and the Cluster's Total Take

William Alexander Aldred
article en

Abstract

Deficiency is the bookkeeping unit of cluster gas loss: how much atomic hydrogen a spiral holds, against how much a field twin of the same size would hold. Six Virgo spirals with solid measurements let the cluster's total take be summed, not just sampled. The expected atomic mass follows the diameter calibration for undisturbed late-type galaxies. Deficiency is the logarithm of expected over observed. Stripped mass is the difference of the two, and summing over the six systems gives the sample's total removed atomic mass and its mass-weighted mean deficiency. Headline values are hidef systems count hidef = 6; hidef calibration intercept hidef = 7.3; hidef calibration slope hidef = 1.55; hidef sample expected atomic mass 1e9 msun hidef = 28.59; hidef sample observed atomic mass 1e9 msun hidef = 6.95; hidef sample stripped atomic mass 1e9 msun hidef = 21.64. The sample retained fraction near a quarter is the headline, because it is immune to the calibration scatter that softens each individual deficiency.

Zenodo (CERN European Organization for Nuclear Research)
Galaxies: Formation, Evolution, Phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon