Improving the Lateral-Resistant Behavior of Steel Plate Shear Walls with CFST Columns Using Two-Layer Flat-Corrugated Plates

Utilizing flat plates (FPs) in a steel plate shear wall (SPSW) system significantly pinches the hysteresis curves, as these plates are highly susceptible to out-of-plane buckling. In this study, a flat-corrugated plate (FCP) was used in an SPSW system with concrete-filled steel tubes (CFST) columns. In this study, an earlier evaluated traditional flat SPSW with CFST columns was validated in ABAQUS software under cyclic loads. Then, by introducing a two-layer FCP that encompasses both a flat and a trapezoidal corrugated plate, instead of an flat plate (FP), the effects on the hysteresis curve and structural parameters were investigated. The results showed that using an FCP instead of a traditional FP in an SPSW system (FCSPSW) with CFST columns led to a fatter hysteresis curve and, subsequently, a significant improvement in energy dissipation. The maximum resistance of the FCSPSWs with CFST columns was slightly higher than that of the control sample. The results showed that the use of an FCP has a minimal effect on the elastic stiffness.

Authors

Institutions

Publication Details

Journal
European Journal of Computational Mechanics
Published
2026-11-16
DOI
https://doi.org/10.13052/ejcm2642-2085.3531
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Improving the Lateral-Resistant Behavior of Steel Plate Shear Walls with CFST Columns Using Two-Layer Flat-Corrugated Plates

Dongyu Ji, 王兴佩, Huanqing Jiang
5 links
European Journal of Computational Mechanics
Structural Load-Bearing Analysis
article

Improving the Lateral-Resistant Behavior of Steel Plate Shear Walls with CFST Columns Using Two-Layer Flat-Corrugated Plates

Dongyu Ji, 王兴佩, Huanqing Jiang
article en

Abstract

Utilizing flat plates (FPs) in a steel plate shear wall (SPSW) system significantly pinches the hysteresis curves, as these plates are highly susceptible to out-of-plane buckling. In this study, a flat-corrugated plate (FCP) was used in an SPSW system with concrete-filled steel tubes (CFST) columns. In this study, an earlier evaluated traditional flat SPSW with CFST columns was validated in ABAQUS software under cyclic loads. Then, by introducing a two-layer FCP that encompasses both a flat and a trapezoidal corrugated plate, instead of an flat plate (FP), the effects on the hysteresis curve and structural parameters were investigated. The results showed that using an FCP instead of a traditional FP in an SPSW system (FCSPSW) with CFST columns led to a fatter hysteresis curve and, subsequently, a significant improvement in energy dissipation. The maximum resistance of the FCSPSWs with CFST columns was slightly higher than that of the control sample. The results showed that the use of an FCP has a minimal effect on the elastic stiffness.

European Journal of Computational Mechanics
Henan Energy & Chemical Industry Group (China) (CN), Hunan Urban Construction College (CN)
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon