Interaction of cylinder count, compressor size, and refrigerant selection in high-capacity rotary compressors: A leakage-friction trade-off analysis

Rotary compressors are widely used in small- to medium-capacity systems owing to their simple mechanical construction and compactness. However, their efficiency declines as capacity increases. While twin-cylinder configurations are the current standard for rotary compressors, the thermodynamic effect of distributing the displacement volume among more than two cylinders has received little attention. This study presents a thermodynamic analysis of rotary compressors with one to five cylinders, focusing on how dividing a fixed displacement volume among more cylinders shifts the balance between leakage and friction losses, and how this balance depends on the compressor size. A geometry model and a detailed mechanistic simulation model based on PDSim are developed and validated against experimental data from a twin-cylinder compressor. Four refrigerants are evaluated, namely R410A, R290, R1234yf, and R600a. For each refrigerant, the displacement volume is sized based on the 5th-percentile dry-bulb ambient temperature and the corresponding heating load of a single-family home in Rochester, Minnesota. Three displacement volumes, 50%, 100%, and 150% of the baseline value, are each combined with one to five cylinders. The seasonal coefficient of performance (SCOP) of each configuration is calculated using hourly ambient temperature and building load data from EnergyPlus simulations. The results show that the benefit of additional cylinders depends strongly on compressor size, as the reduction in friction losses increasingly outweighs the rise in leakage losses with growing compressor size. For the smallest compressor (R410A, 50% size), adding cylinders provides no seasonal benefit, whereas the largest improvement is obtained for the R1234yf 150% size compressor, where increasing the cylinder count from one to five raises SCOP by 47.4%. The highest overall SCOP is achieved by the R410A 150% size compressor with five cylinders (SCOP = 2.53), and the highest among low-GWP refrigerants by the R290 150% size compressor with five cylinders (SCOP = 2.32). • Interaction between compressor size and cylinder count in rotary compressors. • Three compressor sizes combined with one to five cylinders for four refrigerants. • Larger compressors benefit more from additional cylinders than smaller ones. • Friction reduction increasingly outweighs added leakage as compressor size grows. • Seasonal performance gain from more cylinders depends strongly on compressor size.

Authors

Institutions

Publication Details

Journal
Applied Thermal Engineering
Published
2026-11-16
DOI
https://doi.org/10.1016/j.applthermaleng.2026.133976
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Interaction of cylinder count, compressor size, and refrigerant selection in high-capacity rotary compressors: A leakage-friction trade-off analysis

Koosha Mirjavadi, Craig R. Bradshaw, Shahzad Yousaf, Ata Alkhatib
1 links
Applied Thermal Engineering
Refrigeration and Air Conditioning Technologies
article

Interaction of cylinder count, compressor size, and refrigerant selection in high-capacity rotary compressors: A leakage-friction trade-off analysis

Koosha Mirjavadi, Craig R. Bradshaw, Shahzad Yousaf, Ata Alkhatib
article en

Abstract

Rotary compressors are widely used in small- to medium-capacity systems owing to their simple mechanical construction and compactness. However, their efficiency declines as capacity increases. While twin-cylinder configurations are the current standard for rotary compressors, the thermodynamic effect of distributing the displacement volume among more than two cylinders has received little attention. This study presents a thermodynamic analysis of rotary compressors with one to five cylinders, focusing on how dividing a fixed displacement volume among more cylinders shifts the balance between leakage and friction losses, and how this balance depends on the compressor size. A geometry model and a detailed mechanistic simulation model based on PDSim are developed and validated against experimental data from a twin-cylinder compressor. Four refrigerants are evaluated, namely R410A, R290, R1234yf, and R600a. For each refrigerant, the displacement volume is sized based on the 5th-percentile dry-bulb ambient temperature and the corresponding heating load of a single-family home in Rochester, Minnesota. Three displacement volumes, 50%, 100%, and 150% of the baseline value, are each combined with one to five cylinders. The seasonal coefficient of performance (SCOP) of each configuration is calculated using hourly ambient temperature and building load data from EnergyPlus simulations. The results show that the benefit of additional cylinders depends strongly on compressor size, as the reduction in friction losses increasingly outweighs the rise in leakage losses with growing compressor size. For the smallest compressor (R410A, 50% size), adding cylinders provides no seasonal benefit, whereas the largest improvement is obtained for the R1234yf 150% size compressor, where increasing the cylinder count from one to five raises SCOP by 47.4%. The highest overall SCOP is achieved by the R410A 150% size compressor with five cylinders (SCOP = 2.53), and the highest among low-GWP refrigerants by the R290 150% size compressor with five cylinders (SCOP = 2.32). • Interaction between compressor size and cylinder count in rotary compressors. • Three compressor sizes combined with one to five cylinders for four refrigerants. • Larger compressors benefit more from additional cylinders than smaller ones. • Friction reduction increasingly outweighs added leakage as compressor size grows. • Seasonal performance gain from more cylinders depends strongly on compressor size.

Applied Thermal EngineeringVol. 310
University of Illinois Urbana-Champaign (US), Air Conditioning and Refrigeration Center (US)
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon