Low-cost particle image velocimetry based on alternating recording with two low-speed cameras

Abstract This study develops a low-cost particle image velocimetry technique based on alternating recording with two low-speed cameras (AR-PIV). A beam-splitting prism is employed to enable the two cameras to capture particle images from similar perspectives while avoiding mechanical interference. These two cameras alternately capture particle images at successive time instants, thereby providing functionality equivalent to that of a conventional double-frame PIV camera. To mitigate the field-of-view mismatch in dual-camera imaging, we propose an image registration method based on synchronous and asynchronous image acquisitions. The method incorporates Jacobian correction to compensate for the parallax displacement, thereby enabling more accurate estimation of the true flow velocity. An error propagation model is established based on the pinhole camera model, accounting for systematic errors caused by camera misalignment. Numerical simulations incorporating the particle projection and velocity estimation processes are conducted to evaluate the effects of particle concentration, image noise, and camera misalignment on measurement accuracy. While AR-PIV exhibits larger measurement uncertainties than conventional PIV under uniform flow conditions, it achieves comparable accuracy for complex flow measurements. Finally, AR-PIV is validated through a cylinder wake experiment. The instantaneous velocity fields and statistical quantities obtained from AR-PIV agree well with those measured by conventional PIV. This study indicates that AR-PIV can significantly reduce system cost while maintaining high measurement accuracy, providing an effective solution for low-cost flow-field measurements.

Authors

Institutions

Publication Details

Journal
Measurement Science and Technology
Published
2026-11-16
DOI
https://doi.org/10.1088/1361-6501/aec28b
Primary Topic
Fluid Dynamics and Turbulent Flows
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Low-cost particle image velocimetry based on alternating recording with two low-speed cameras

Chengyue Wang, Giuseppe Carbone, Jun Dong, Dekang Li et al.
2 links
Measurement Science and Technology
Fluid Dynamics and Turbulent Flows
article

Low-cost particle image velocimetry based on alternating recording with two low-speed cameras

Chengyue Wang, Giuseppe Carbone, Jun Dong, Dekang Li, Junjie Zhu
article en

Abstract

Abstract This study develops a low-cost particle image velocimetry technique based on alternating recording with two low-speed cameras (AR-PIV). A beam-splitting prism is employed to enable the two cameras to capture particle images from similar perspectives while avoiding mechanical interference. These two cameras alternately capture particle images at successive time instants, thereby providing functionality equivalent to that of a conventional double-frame PIV camera. To mitigate the field-of-view mismatch in dual-camera imaging, we propose an image registration method based on synchronous and asynchronous image acquisitions. The method incorporates Jacobian correction to compensate for the parallax displacement, thereby enabling more accurate estimation of the true flow velocity. An error propagation model is established based on the pinhole camera model, accounting for systematic errors caused by camera misalignment. Numerical simulations incorporating the particle projection and velocity estimation processes are conducted to evaluate the effects of particle concentration, image noise, and camera misalignment on measurement accuracy. While AR-PIV exhibits larger measurement uncertainties than conventional PIV under uniform flow conditions, it achieves comparable accuracy for complex flow measurements. Finally, AR-PIV is validated through a cylinder wake experiment. The instantaneous velocity fields and statistical quantities obtained from AR-PIV agree well with those measured by conventional PIV. This study indicates that AR-PIV can significantly reduce system cost while maintaining high measurement accuracy, providing an effective solution for low-cost flow-field measurements.

Measurement Science and Technology
Nanjing University of Science and Technology (CN)
National Natural Science Foundation of China, Fundamental Research Funds for the Central Universities
Fluid Dynamics and Turbulent Flows
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon