Causal Energy Accessibility and Capacity Allocation for Transient Voltage Security in Converter Networks

Unused remote headroom may coexist with local overvoltage when transfer power or its timing prevents surplus energy from reaching the remote resource. This study derives a causal energy-transfer envelope retaining initial releasable energy, injection timing, and converter-mode limits. The envelope gives an exact feasibility condition for an ideal two-region system; its constant-capacity specialization separates resource insufficiency from fixed-controller violations, and a bandwidth penalty gives the lag and power-ramp capability a causal controller needs to realize the ideal transfer. A temporal network optimization retains a common storage history, minimizes persistent absorption additions, prices their location through its dual, and translates them into capacitance with coupled energy margins. In 2592 two-region cases, 670 of 2160 aggregate-capacity passes exhibit fixed-droop overvoltage, including 144 with a feasible ideal transfer, of which a causal controller with a 0.5 ms lag realizes 134. In 576 network cases, shared-equipment prefix bounds leave 59 infeasible cases unresolved. In a three-terminal resistance–inductance (R–L) circuit with finite converter–current response, a necessary voltage bound preserving the sign of the impulse response excludes 30 of 60 cases; validated ball arithmetic confirms every exclusion, the extension through the recovery interval changes none, and an available-power ceiling raises the count to 37. Cases that satisfy the bound remain unresolved until a controller is simulated. A switching-function modular multilevel converter model reproduces the averaged peaks within 0.8% at 30 kJ/MVA station energies and within 4.1% at the lower nominal energies, and 1200 randomly perturbed cases contain no exclusion that meets a safe trajectory.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2026-11-16
DOI
https://doi.org/10.3390/electronics15225321
Primary Topic
Power System Optimization and Stability
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Causal Energy Accessibility and Capacity Allocation for Transient Voltage Security in Converter Networks

Binqi Ma, Fan Li, Rui Shi, Jishuo Qin et al.
Electronics
Power System Optimization and Stability
article

Causal Energy Accessibility and Capacity Allocation for Transient Voltage Security in Converter Networks

Binqi Ma, Fan Li, Rui Shi, Jishuo Qin, Guodong Guo, Dan Wang
article en

Abstract

Unused remote headroom may coexist with local overvoltage when transfer power or its timing prevents surplus energy from reaching the remote resource. This study derives a causal energy-transfer envelope retaining initial releasable energy, injection timing, and converter-mode limits. The envelope gives an exact feasibility condition for an ideal two-region system; its constant-capacity specialization separates resource insufficiency from fixed-controller violations, and a bandwidth penalty gives the lag and power-ramp capability a causal controller needs to realize the ideal transfer. A temporal network optimization retains a common storage history, minimizes persistent absorption additions, prices their location through its dual, and translates them into capacitance with coupled energy margins. In 2592 two-region cases, 670 of 2160 aggregate-capacity passes exhibit fixed-droop overvoltage, including 144 with a feasible ideal transfer, of which a causal controller with a 0.5 ms lag realizes 134. In 576 network cases, shared-equipment prefix bounds leave 59 infeasible cases unresolved. In a three-terminal resistance–inductance (R–L) circuit with finite converter–current response, a necessary voltage bound preserving the sign of the impulse response excludes 30 of 60 cases; validated ball arithmetic confirms every exclusion, the extension through the recovery interval changes none, and an available-power ceiling raises the count to 37. Cases that satisfy the bound remain unresolved until a controller is simulated. A switching-function modular multilevel converter model reproduces the averaged peaks within 0.8% at 30 kJ/MVA station energies and within 4.1% at the lower nominal energies, and 1200 randomly perturbed cases contain no exclusion that meets a safe trajectory.

ElectronicsVol. 15(22)
North China Electric Power University (CN), State Grid Corporation of China (China) (CN)
State Grid Corporation of China
Affordable and clean energy, Industry, innovation and infrastructure
Power System Optimization and Stability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon