Computational Biomechanical Analysis of the MD Codes Sequence

The MD Codes™ system is a widely used framework for facial filler treatment, but the biomechanics of its Foundation–Contour–Refinement sequence are unexplored. We performed finite element simulations at 26 MD Codes injection points in 20,000 virtual models, generated by morphing a single baseline facial mesh, and introduce the Tissue Response Vector™ (TRV), an exploratory descriptor of projection (Mp), lift (‖Vl‖), tissue strain (Es), and peri-injection pressure (P). Foundation codes (Ck1, Ck1 TML, and Ck4) had the highest TRV scores (0.81–0.92), lift (0.65–0.82 mm/mL), and strain (10.2–14.3%). Of the three phase orders simulated, the MD Codes sequence produced the highest overall TRV (0.69 ± 0.12), 10–16% above the alternatives. For Ck1, the composite peaked at 0.3 cc; larger volumes reduced lift and increased pressure. Among the nine codes with directly measured surface volume coefficient (SVC) values, the SVC was imprecisely associated with Mp (r = 0.47, 95% CI −0.28 to 0.86) and not with ‖Vl‖ or Es. Six codes sharing one SVC value differed more than twofold in lift and threefold in strain, so the SVC alone could not distinguish their biomechanical roles. These findings provide a biomechanical rationale for the MD Codes sequence that can now be tested in clinical studies.

Authors

Institutions

Publication Details

Journal
Cosmetics
Published
2026-11-16
DOI
https://doi.org/10.3390/cosmetics13060319
Primary Topic
Facial Rejuvenation and Surgery Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Computational Biomechanical Analysis of the MD Codes Sequence

Parinitha Rao, Eqram Rahman, Woffles T. L. Wu, JEAN D. A. CARRUTHERS et al.
2 links
Cosmetics
Facial Rejuvenation and Surgery Techniques
article

Computational Biomechanical Analysis of the MD Codes Sequence

Parinitha Rao, Eqram Rahman, Woffles T. L. Wu, JEAN D. A. CARRUTHERS, Afshin Mosahebi, William Richard Webb
article en

Abstract

The MD Codes™ system is a widely used framework for facial filler treatment, but the biomechanics of its Foundation–Contour–Refinement sequence are unexplored. We performed finite element simulations at 26 MD Codes injection points in 20,000 virtual models, generated by morphing a single baseline facial mesh, and introduce the Tissue Response Vector™ (TRV), an exploratory descriptor of projection (Mp), lift (‖Vl‖), tissue strain (Es), and peri-injection pressure (P). Foundation codes (Ck1, Ck1 TML, and Ck4) had the highest TRV scores (0.81–0.92), lift (0.65–0.82 mm/mL), and strain (10.2–14.3%). Of the three phase orders simulated, the MD Codes sequence produced the highest overall TRV (0.69 ± 0.12), 10–16% above the alternatives. For Ck1, the composite peaked at 0.3 cc; larger volumes reduced lift and increased pressure. Among the nine codes with directly measured surface volume coefficient (SVC) values, the SVC was imprecisely associated with Mp (r = 0.47, 95% CI −0.28 to 0.86) and not with ‖Vl‖ or Es. Six codes sharing one SVC value differed more than twofold in lift and threefold in strain, so the SVC alone could not distinguish their biomechanical roles. These findings provide a biomechanical rationale for the MD Codes sequence that can now be tested in clinical studies.

CosmeticsVol. 13(6)
University of British Columbia (CA), Royal Free London NHS Foundation Trust (GB), The Royal Free Hospital (GB)
Facial Rejuvenation and Surgery Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon