Multilevel Reproducibility Assessment of Polymer Monolithic Capillary Columns for Peptide Separations

Polymer monoliths have emerged as attractive stationary phases for peptide and intact-protein analysis, offering an alternative to packed-bed columns. Their synthesis involves several critical manual steps raising concerns about reproducibility and transferability of the synthesis protocol. This study systematically evaluates the robustness and reproducibility of an established synthesis protocol where two operators synthesized two of column batches of 100 µm i.d. poly(styrene-co-divinylbenzene) monolithic capillary columns and assessing their performance in peptide separations. Column robustness was investigated through 70 consecutive peptide separations performed on a representative polymer monolithic capillary column. The column maintained its chromatographic performance, achieving retention-time stability comparable to commercial packed nanoLC columns (CV < 0.5%). The within-batch reproducibility of the columns was found to be generally high, with the coefficient of variance (CV) of the pressure drop below 10% and CV of retention times and peak width below 3% and 8-15%, respectively. Multivariate testing by multivariate analysis of variance (MANOVA) was performed to compare batches of the same operator and columns from different operators, detecting no significant difference between the operators (p = 0.2802). Our study demonstrates the reproducibility of polymer monolith fabrication across multiple levels, establishing the robustness and transferability of the synthesis protocol.

Authors

Institutions

Publication Details

Journal
ChemRxiv
Published
2026-11-16
DOI
https://doi.org/10.26434/chemrxiv.15012254/v1
Primary Topic
Analytical Chemistry and Chromatography
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Multilevel Reproducibility Assessment of Polymer Monolithic Capillary Columns for Peptide Separations

Ken Broeckhoven, Dániel Papp, Sebastiaan Eeltink, Luiz Fernando Ribeiro et al.
ChemRxiv
Analytical Chemistry and Chromatography
preprint

Multilevel Reproducibility Assessment of Polymer Monolithic Capillary Columns for Peptide Separations

Ken Broeckhoven, Dániel Papp, Sebastiaan Eeltink, Luiz Fernando Ribeiro, Bo Zhang
preprint en

Abstract

Polymer monoliths have emerged as attractive stationary phases for peptide and intact-protein analysis, offering an alternative to packed-bed columns. Their synthesis involves several critical manual steps raising concerns about reproducibility and transferability of the synthesis protocol. This study systematically evaluates the robustness and reproducibility of an established synthesis protocol where two operators synthesized two of column batches of 100 µm i.d. poly(styrene-co-divinylbenzene) monolithic capillary columns and assessing their performance in peptide separations. Column robustness was investigated through 70 consecutive peptide separations performed on a representative polymer monolithic capillary column. The column maintained its chromatographic performance, achieving retention-time stability comparable to commercial packed nanoLC columns (CV < 0.5%). The within-batch reproducibility of the columns was found to be generally high, with the coefficient of variance (CV) of the pressure drop below 10% and CV of retention times and peak width below 3% and 8-15%, respectively. Multivariate testing by multivariate analysis of variance (MANOVA) was performed to compare batches of the same operator and columns from different operators, detecting no significant difference between the operators (p = 0.2802). Our study demonstrates the reproducibility of polymer monolith fabrication across multiple levels, establishing the robustness and transferability of the synthesis protocol.

ChemRxiv
Vrije Universiteit Brussel (BE), Xiamen University (CN)
Analytical Chemistry and Chromatography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon