Current documented functional status after radiocephalic straight-line onlay fistula creation: A retrospective cohort study

OBJECTIVE: The straight-line onlay technique (SLOT) may optimize radiocephalic fistula geometry, but available evidence remains limited. This study evaluated documented current functional status after radiocephalic SLOT creation and examined how alternative denominator constructions changed the reported proportion of functional fistulas. METHODS: This retrospective cohort included 145 adult patients who underwent radiocephalic SLOT fistula creation between March 2020 and January 2024. Functional use was defined as documented access flow ⩾300 mL/min together with at least two successful two-needle hemodialysis sessions. Final status was classified as functional, failure, death-censored, transplant-censored, or unknown follow-up status. Continuous variables are reported descriptively, and proportions are presented with Wilson confidence intervals. RESULTS: Documented functional use was confirmed in 113 of 145 patients (77.9%; 95% CI 70.5-83.9) in the full cohort. Among 124 patients with determinable current status, 113 had confirmed functional fistulas and 11 had confirmed failure, corresponding to 91.1% (95% CI 84.8-95.0). Failures comprised three early thromboses and eight nonmaturation events. Median radial artery and cephalic vein diameters were 2.4 mm and 3.3 mm. CONCLUSIONS: In this retrospective cohort, documented functional use was confirmed in 77.9% of the full radiocephalic SLOT cohort. The higher 91.1% estimate reflected restriction to patients with determinable final status rather than a change in the number of confirmed functional fistulas. These findings should be interpreted as descriptive current functional status, not as conventional longitudinal primary or secondary patency, and require prospective study using standardized patency definitions.

Authors

Institutions

Publication Details

Journal
The Journal of Vascular Access
Published
2026-11-16
DOI
https://doi.org/10.1177/11297298261501595
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Current documented functional status after radiocephalic straight-line onlay fistula creation: A retrospective cohort study

Abdullah Burak Balcı, Mesut Kösem, Burak Taşçı
1 links
The Journal of Vascular Access
Central Venous Catheters and Hemodialysis
article

Current documented functional status after radiocephalic straight-line onlay fistula creation: A retrospective cohort study

Abdullah Burak Balcı, Mesut Kösem, Burak Taşçı
article en

Abstract

OBJECTIVE: The straight-line onlay technique (SLOT) may optimize radiocephalic fistula geometry, but available evidence remains limited. This study evaluated documented current functional status after radiocephalic SLOT creation and examined how alternative denominator constructions changed the reported proportion of functional fistulas. METHODS: This retrospective cohort included 145 adult patients who underwent radiocephalic SLOT fistula creation between March 2020 and January 2024. Functional use was defined as documented access flow ⩾300 mL/min together with at least two successful two-needle hemodialysis sessions. Final status was classified as functional, failure, death-censored, transplant-censored, or unknown follow-up status. Continuous variables are reported descriptively, and proportions are presented with Wilson confidence intervals. RESULTS: Documented functional use was confirmed in 113 of 145 patients (77.9%; 95% CI 70.5-83.9) in the full cohort. Among 124 patients with determinable current status, 113 had confirmed functional fistulas and 11 had confirmed failure, corresponding to 91.1% (95% CI 84.8-95.0). Failures comprised three early thromboses and eight nonmaturation events. Median radial artery and cephalic vein diameters were 2.4 mm and 3.3 mm. CONCLUSIONS: In this retrospective cohort, documented functional use was confirmed in 77.9% of the full radiocephalic SLOT cohort. The higher 91.1% estimate reflected restriction to patients with determinable final status rather than a change in the number of confirmed functional fistulas. These findings should be interpreted as descriptive current functional status, not as conventional longitudinal primary or secondary patency, and require prospective study using standardized patency definitions.

The Journal of Vascular Access
Bakırköy Dr.Sadi Konuk Eğitim ve Araştırma Hastanesi (TR), İstanbul Başakşehir Çam ve Sakura Şehir Hastanesi (TR)
Good health and well-being
Central Venous Catheters and Hemodialysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon