Influence of Shear-Wall Configuration on Ground-Floor Column Design and Material Quantities in a 12-Storey Reinforced Concrete Building

Shear walls can be utilized to enhance the lateral strength of tall buildings; however, their arrangement can also have an effect on gravity load demands on the ground floor columns. This study sought to conduct an analysis to compare column demands and material quantities for four different types of shear wall arrangements in a 12-story reinforced concrete structure in Cambodia with four configurations of shear walls: without additional walls (M1), core walls (M2), perimeter walls (M3), and combined walls (M4). The three-dimensional linear elastic models were analyzed in Autodesk Robot Structural Analysis Professional 2021 using the factored gravity load combination of 1.2DL + 1.6LL. Four important cases of ground-floor columns (GFC13 in M1, M2, and M3, and GFC23 in M3) were then evaluated for slenderness, moment magnification, P-M interaction, and shear using ACI 318-08 guidelines. Compared to the reference model, the combined walls model decreased the column concrete volume from 50.63 m³ to 40.36 m³ (20.3%) and column steel reinforcement from 10.75 t to 9.65 t (10.2%). But such reductions cannot be made solely based on axial capacity since both reduced 300 x 300 mm column GFC23 in M3 fails the P-M check (Mc/ϕMn ≈ 2.1) and GFC13 in M3 has a very small amount of moment capacity (≈ 0.96), while other reduced columns have not been tested for that. For practicing engineers, walls adjacent to heavily loaded columns reduce their load locally, so it is useful to take advantage of the pattern of walls to determine which columns are to be checked for reductions; all reductions must go along with slenderness and P-M tests and combined wind/seismic forces. The stated reductions are not verified design savings

Authors

Publication Details

Journal
Scientific journal of engineering and technology.
Published
2026-11-16
DOI
https://doi.org/10.69739/sjet.v3i2.2546
Primary Topic
Seismic and Structural Analysis of Tall Buildings
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Influence of Shear-Wall Configuration on Ground-Floor Column Design and Material Quantities in a 12-Storey Reinforced Concrete Building

Muy Chheng Moeurn, Phok Sambo
2 links
Scientific journal of engineering and technology.
Seismic and Structural Analysis of Tall Buildings
article

Influence of Shear-Wall Configuration on Ground-Floor Column Design and Material Quantities in a 12-Storey Reinforced Concrete Building

Muy Chheng Moeurn, Phok Sambo
article en

Abstract

Shear walls can be utilized to enhance the lateral strength of tall buildings; however, their arrangement can also have an effect on gravity load demands on the ground floor columns. This study sought to conduct an analysis to compare column demands and material quantities for four different types of shear wall arrangements in a 12-story reinforced concrete structure in Cambodia with four configurations of shear walls: without additional walls (M1), core walls (M2), perimeter walls (M3), and combined walls (M4). The three-dimensional linear elastic models were analyzed in Autodesk Robot Structural Analysis Professional 2021 using the factored gravity load combination of 1.2DL + 1.6LL. Four important cases of ground-floor columns (GFC13 in M1, M2, and M3, and GFC23 in M3) were then evaluated for slenderness, moment magnification, P-M interaction, and shear using ACI 318-08 guidelines. Compared to the reference model, the combined walls model decreased the column concrete volume from 50.63 m³ to 40.36 m³ (20.3%) and column steel reinforcement from 10.75 t to 9.65 t (10.2%). But such reductions cannot be made solely based on axial capacity since both reduced 300 x 300 mm column GFC23 in M3 fails the P-M check (Mc/ϕMn ≈ 2.1) and GFC13 in M3 has a very small amount of moment capacity (≈ 0.96), while other reduced columns have not been tested for that. For practicing engineers, walls adjacent to heavily loaded columns reduce their load locally, so it is useful to take advantage of the pattern of walls to determine which columns are to be checked for reductions; all reductions must go along with slenderness and P-M tests and combined wind/seismic forces. The stated reductions are not verified design savings

Scientific journal of engineering and technology.Vol. 3(2)
Sustainable cities and communities
Seismic and Structural Analysis of Tall Buildings
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon