THERMAL SAFETY OF SIMULATED ENDOSCOPIC LASER LITHOTRIPSY: AN IN VIVO PORCINE STUDY

Abstract Background Laser activation during retrograde intrarenal surgery may increase intrarenal temperature and cause thermal injury. In vivo data linking critical temperature thresholds to morphological changes remain limited. Objective: To compare temperature dynamics in the renal collecting system and parenchyma during simulated lithotripsy with Ho:YAG and TFL in an in vivo porcine model. Methods Ten pigs were included. Temperature was recorded simultaneously in the collecting system and renal parenchyma using thermocouples. Ho:YAG and TFL were evaluated at 25 and 35 W with irrigation rates of 15 and 20 mL/min during 120 seconds of continuous activation without a stone or stone phantom. Intrarenal and parenchymal temperatures, time to 43 and 56°C, critical thermal dose (CEM43 > 120), and histopathological changes were assessed. Results Median intrarenal temperature remained below 43°C only at 25 W and 20 mL/min for both lasers. Median temperature did not reach 56°C, while peaks above 56°C occurred only with Ho:YAG at 35 W and 15 mL/min. Increasing power from 25 to 35 W increased median intrarenal temperature by approximately 9–10°C, whereas increasing irrigation from 15 to 20 mL/min reduced it by approximately 5°C. Differences between lasers were comparatively modest (1.88–2.25°C). CEM43 > 120 occurred at 35 W and 15 mL/min for both lasers and at 35 W and 20 mL/min for Ho:YAG. Parenchymal temperature remained below 43°C in all experiments. Histologically confirmed injury occurred exclusively at 35 W and 15 mL/min and was comparable between lasers; maximum injury depth was 410.4 µm for TFL and 590.3 µm for Ho:YAG. Conclusions Laser power, irrigation rate, and continuous activation time had a greater influence on thermal risk than laser type. The 35 W/15 mL/min condition showed the highest risk, whereas 25 W with 15–20 mL/min provided a more favorable safety profile in this model.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-16
DOI
https://doi.org/10.21203/rs.3.rs-11236664/v1
Primary Topic
Kidney Stones and Urolithiasis Treatments
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

THERMAL SAFETY OF SIMULATED ENDOSCOPIC LASER LITHOTRIPSY: AN IN VIVO PORCINE STUDY

Игорь Олегович Грицков, Д Ю Пушкарь, Виген Андреевич Малхасян, Ali Talyshinskii et al.
4 links
Research Square
Kidney Stones and Urolithiasis Treatments
preprint

THERMAL SAFETY OF SIMULATED ENDOSCOPIC LASER LITHOTRIPSY: AN IN VIVO PORCINE STUDY

Игорь Олегович Грицков, Д Ю Пушкарь, Виген Андреевич Малхасян, Ali Talyshinskii, Bhaskar Kumar Somani, Arman Tsaturyan, Sergey O. Sukhikh¹, Leonid V. Reshetov¹, Vineet Gauhar, Nariman K. Gadzhiev
preprint en

Abstract

Abstract Background Laser activation during retrograde intrarenal surgery may increase intrarenal temperature and cause thermal injury. In vivo data linking critical temperature thresholds to morphological changes remain limited. Objective: To compare temperature dynamics in the renal collecting system and parenchyma during simulated lithotripsy with Ho:YAG and TFL in an in vivo porcine model. Methods Ten pigs were included. Temperature was recorded simultaneously in the collecting system and renal parenchyma using thermocouples. Ho:YAG and TFL were evaluated at 25 and 35 W with irrigation rates of 15 and 20 mL/min during 120 seconds of continuous activation without a stone or stone phantom. Intrarenal and parenchymal temperatures, time to 43 and 56°C, critical thermal dose (CEM43 > 120), and histopathological changes were assessed. Results Median intrarenal temperature remained below 43°C only at 25 W and 20 mL/min for both lasers. Median temperature did not reach 56°C, while peaks above 56°C occurred only with Ho:YAG at 35 W and 15 mL/min. Increasing power from 25 to 35 W increased median intrarenal temperature by approximately 9–10°C, whereas increasing irrigation from 15 to 20 mL/min reduced it by approximately 5°C. Differences between lasers were comparatively modest (1.88–2.25°C). CEM43 > 120 occurred at 35 W and 15 mL/min for both lasers and at 35 W and 20 mL/min for Ho:YAG. Parenchymal temperature remained below 43°C in all experiments. Histologically confirmed injury occurred exclusively at 35 W and 15 mL/min and was comparable between lasers; maximum injury depth was 410.4 µm for TFL and 590.3 µm for Ho:YAG. Conclusions Laser power, irrigation rate, and continuous activation time had a greater influence on thermal risk than laser type. The 35 W/15 mL/min condition showed the highest risk, whereas 25 W with 15–20 mL/min provided a more favorable safety profile in this model.

Research Square
St Petersburg University (RU), Ng Teng Fong General Hospital (SG), University Hospital Southampton NHS Foundation Trust (GB), Botkin Hospital (RU), Yerevan State Medical University (AM)
Good health and well-being
Kidney Stones and Urolithiasis Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon