Feasibility of Using Solar Photovoltaics to Decarbonize the Natural Gas Compressor Station Along the East–West Pipeline in Saudi Arabia

This study evaluates the techno-economic and environmental feasibility of integrating a grid-connected solar photovoltaic (PV) system to decarbonize natural gas compressor stations along Saudi Arabia’s East-West pipeline. The objective of this study is to assess whether solar PV can reliably offset the station’s annual electricity demand of 23,520 MWh while maintaining economic viability. The System Advisor Model (SAM) software was utilized to simulate two representative locations, Abqaiq and Al-Duwadimi, under fixed tilt and single-axis tracking configurations. All systems were sized to meet and slightly exceed the required demand over a 25-year lifetime, while exporting the excess energy produced to the grid. Results show that single-axis tracking delivers similar Year-1 AC energy with a smaller DC array, and under equal PV module capacity, it produces higher annual AC output than fixed-tilt systems. Seasonality variability leads to higher grid-imported energy during low-irradiance periods, while a 0.5%/year DC degradation causes a gradual decline in PV generation over time. Financial analysis under a net-zero billing framework illustrates a reduction of approximately 50% in payback time compared to conventional billing, with 1st year significant savings of $ 1.78–1.83 M and additional export revenues of $ 0.33–0.36 M. The calculated LCOE ranges from 2.94–3.62 (¢/kWh), with the Abqaiq single-axis scenario offering superior performance. Environmentally, displacing grid electricity with solar PV avoids 670,729–688,292 tons of CO₂ over the entire project’s lifecycle, while lifetime PV emissions represent only 1–1.5% of the avoided grid emissions, confirming a substantial net environmental benefit.

Authors

Institutions

Publication Details

Published
2026-11-16
DOI
https://doi.org/10.64589/juri/231582
Primary Topic
Photovoltaic Systems and Sustainability
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Feasibility of Using Solar Photovoltaics to Decarbonize the Natural Gas Compressor Station Along the East–West Pipeline in Saudi Arabia

Sulaiman A. Alturaifi, Awad Bin Saud Alquaity, Semat Abdulaziz Al Salam
3 links
Photovoltaic Systems and Sustainability
article

Feasibility of Using Solar Photovoltaics to Decarbonize the Natural Gas Compressor Station Along the East–West Pipeline in Saudi Arabia

Sulaiman A. Alturaifi, Awad Bin Saud Alquaity, Semat Abdulaziz Al Salam
article en

Abstract

This study evaluates the techno-economic and environmental feasibility of integrating a grid-connected solar photovoltaic (PV) system to decarbonize natural gas compressor stations along Saudi Arabia’s East-West pipeline. The objective of this study is to assess whether solar PV can reliably offset the station’s annual electricity demand of 23,520 MWh while maintaining economic viability. The System Advisor Model (SAM) software was utilized to simulate two representative locations, Abqaiq and Al-Duwadimi, under fixed tilt and single-axis tracking configurations. All systems were sized to meet and slightly exceed the required demand over a 25-year lifetime, while exporting the excess energy produced to the grid. Results show that single-axis tracking delivers similar Year-1 AC energy with a smaller DC array, and under equal PV module capacity, it produces higher annual AC output than fixed-tilt systems. Seasonality variability leads to higher grid-imported energy during low-irradiance periods, while a 0.5%/year DC degradation causes a gradual decline in PV generation over time. Financial analysis under a net-zero billing framework illustrates a reduction of approximately 50% in payback time compared to conventional billing, with 1st year significant savings of $ 1.78–1.83 M and additional export revenues of $ 0.33–0.36 M. The calculated LCOE ranges from 2.94–3.62 (¢/kWh), with the Abqaiq single-axis scenario offering superior performance. Environmentally, displacing grid electricity with solar PV avoids 670,729–688,292 tons of CO₂ over the entire project’s lifecycle, while lifetime PV emissions represent only 1–1.5% of the avoided grid emissions, confirming a substantial net environmental benefit.

Vol. 2(3B)
King Fahd University of Petroleum and Minerals (SA)
King Fahd University of Petroleum and Minerals
Affordable and clean energy, Industry, innovation and infrastructure, Climate action
Photovoltaic Systems and Sustainability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon