A Data Centre Afloat, Cooled by Deep Water and Powered by Its Own Thermal Plant, Sized by Heat-Rejection and Uptime Budgets

A moored barge carries a data hall whose cooling loops draw directly on deep cold water, while a closed-cycle thermal plant on the same hull supplies the facility's power, removing both the grid connection and the chiller plant from the design, a computed study of the facility. Its operating principle: floating data-centre cooled by deep water, where the ocean provides the two things data centres buy most: firm power and a cold sink, from the same thermal gradient. Headline values are fdc surface temperature fdc c = 27; fdc deep temperature fdc c = 5; fdc temperature difference fdc k = 22; fdc carnot efficiency fdc percent = 7.33; fdc adopted cycle fdc efficiency percent = 4.031; fdc warm flow fdc m3 per s fdc = 25. A data centre is a machine for turning electricity into hot water; mooring it over a cold abyss and a thermal gradient answers both halves of that sentence at once. SIMULATED, NOT MEASURED. Ordinary commercial computing — the world's email, ledgers and photographs — is the workload contemplated here. The barge is a utility building that floats, offering rented computing cooled by the sea and nothing more sinister than that.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-16
DOI
https://doi.org/10.5281/zenodo.24291426
Primary Topic
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A Data Centre Afloat, Cooled by Deep Water and Powered by Its Own Thermal Plant, Sized by Heat-Rejection and Uptime Budgets

William Alexander Aldred
3 links
Zenodo (CERN European Organization for Nuclear Research)
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
article

A Data Centre Afloat, Cooled by Deep Water and Powered by Its Own Thermal Plant, Sized by Heat-Rejection and Uptime Budgets

William Alexander Aldred
article en

Abstract

A moored barge carries a data hall whose cooling loops draw directly on deep cold water, while a closed-cycle thermal plant on the same hull supplies the facility's power, removing both the grid connection and the chiller plant from the design, a computed study of the facility. Its operating principle: floating data-centre cooled by deep water, where the ocean provides the two things data centres buy most: firm power and a cold sink, from the same thermal gradient. Headline values are fdc surface temperature fdc c = 27; fdc deep temperature fdc c = 5; fdc temperature difference fdc k = 22; fdc carnot efficiency fdc percent = 7.33; fdc adopted cycle fdc efficiency percent = 4.031; fdc warm flow fdc m3 per s fdc = 25. A data centre is a machine for turning electricity into hot water; mooring it over a cold abyss and a thermal gradient answers both halves of that sentence at once. SIMULATED, NOT MEASURED. Ordinary commercial computing — the world's email, ledgers and photographs — is the workload contemplated here. The barge is a utility building that floats, offering rented computing cooled by the sea and nothing more sinister than that.

Zenodo (CERN European Organization for Nuclear Research)
Affordable and clean energy, Climate action, Industry, innovation and infrastructure
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon