Diagnostic Performance of 96-Channel Magnetocardiography for Angiographically Significant Coronary Stenosis in Patients with Chest Pain and Clinically Suspected Angina: A Two-Center Post Hoc Analysis

Background/Objectives: We evaluated the diagnostic performance of 96-channel magnetocardiography (MCG) for angiographically significant coronary stenosis in patients with chest pain and clinically suspected angina. Methods: This two-center post hoc analysis included 137 participants with paired resting (Rest) and post-exercise recovery recordings. The anatomical reference required visually assessed stenosis ≥70% in a vessel with a reference diameter ≥ 2.5 mm. A predefined Total Score ≥ 2 indicated a positive MCG test. Results: The cohort included 37 reference-positive and 100 reference-negative participants. Rest and post-exercise AUCs were 0.710 (95% CI 0.612–0.801) and 0.815 (0.730–0.889), respectively. The direct paired AUC difference was 0.106 (95% CI 0.004–0.207; paired DeLong p = 0.041). A separate exploratory fitted-model comparison yielded an AUC difference of 0.097 (95% CI 0.031–0.214). At Total Score ≥ 2, Rest sensitivity and specificity were 64.9% and 74.0%. Post-exercise sensitivity, specificity, positive predictive value, and negative predictive value were 83.8% (95% CI 68.9–92.3), 77.0% (67.8–84.2), 57.4% (44.2–69.7), and 92.8% (85.1–96.6), respectively. Post-exercise MCG produced six false-negative and 23 false-positive results. Paired sensitivity and specificity differences were not statistically significant. Conclusions: In this selected cohort, post-exercise MCG showed higher discrimination than Rest MCG for the study-defined anatomical target. The findings support further evaluation as an adjunctive electrophysiological test; they do not establish physiological ischemia detection or justify deferring indicated anatomical assessment.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-11-16
DOI
https://doi.org/10.3390/diagnostics16223812
Primary Topic
Cardiac Imaging and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Diagnostic Performance of 96-Channel Magnetocardiography for Angiographically Significant Coronary Stenosis in Patients with Chest Pain and Clinically Suspected Angina: A Two-Center Post Hoc Analysis

Yeon-Jik Choi, Albert Youngwoo Jang, Suk Min Seo, Yoonsun Won et al.
1 links
Diagnostics
Cardiac Imaging and Diagnostics
article

Diagnostic Performance of 96-Channel Magnetocardiography for Angiographically Significant Coronary Stenosis in Patients with Chest Pain and Clinically Suspected Angina: A Two-Center Post Hoc Analysis

Yeon-Jik Choi, Albert Youngwoo Jang, Suk Min Seo, Yoonsun Won, Woong Chol Kang, Jeonggeun Moon, Joonpyo Lee, Junghoon Lee, Wook-Jin Chung, Osung Kwon, Minsu Kim, Kyung Eun Ha, Seung Hwan Han, Kyounghoon Lee
article en

Abstract

Background/Objectives: We evaluated the diagnostic performance of 96-channel magnetocardiography (MCG) for angiographically significant coronary stenosis in patients with chest pain and clinically suspected angina. Methods: This two-center post hoc analysis included 137 participants with paired resting (Rest) and post-exercise recovery recordings. The anatomical reference required visually assessed stenosis ≥70% in a vessel with a reference diameter ≥ 2.5 mm. A predefined Total Score ≥ 2 indicated a positive MCG test. Results: The cohort included 37 reference-positive and 100 reference-negative participants. Rest and post-exercise AUCs were 0.710 (95% CI 0.612–0.801) and 0.815 (0.730–0.889), respectively. The direct paired AUC difference was 0.106 (95% CI 0.004–0.207; paired DeLong p = 0.041). A separate exploratory fitted-model comparison yielded an AUC difference of 0.097 (95% CI 0.031–0.214). At Total Score ≥ 2, Rest sensitivity and specificity were 64.9% and 74.0%. Post-exercise sensitivity, specificity, positive predictive value, and negative predictive value were 83.8% (95% CI 68.9–92.3), 77.0% (67.8–84.2), 57.4% (44.2–69.7), and 92.8% (85.1–96.6), respectively. Post-exercise MCG produced six false-negative and 23 false-positive results. Paired sensitivity and specificity differences were not statistically significant. Conclusions: In this selected cohort, post-exercise MCG showed higher discrimination than Rest MCG for the study-defined anatomical target. The findings support further evaluation as an adjunctive electrophysiological test; they do not establish physiological ischemia detection or justify deferring indicated anatomical assessment.

DiagnosticsVol. 16(22)
Gachon University Gil Medical Center (KR), The Catholic University of Korea Eunpyeong St. Mary's Hospital (KR), Catholic University of Korea (KR)
Good health and well-being
Cardiac Imaging and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon