Design and Performance Validation of Foam Oil Metering Separator

Aiming at the engineering problems of low metering accuracy and frequent tank overflow in conventional metering separators caused by the high foam content characteristics of produced fluid from CO2 flooding, this paper designs a differential pressure continuous metering separator with a double-tank configuration. By developing a coupled numerical framework that incorporates the Eulerian multiphase flow model, the Realizable k–ε turbulence model, the Luo population balance model (PBM), and a bubble attenuation model calibrated with field-sampled foam half-life and bubble size range, the effects of foam half–life, pressure, and temperature on the internal flow field characteristics and metering performance of a single metering tank are analyzed as an engineering sensitivity study. The overall metering performance of the actual six-tank alternating metering separator is validated by laboratory and field tests. The single-tank simulation results indicate that under the working conditions of high gas–liquid ratio, different foam half–lives, different operating pressures and different temperatures, after the gas, foam and crude oil enter the separator tank, the distribution of foam and crude oil is clearly stratified. The liquid column pressures of foam and crude oil in the single tank can quickly reach a regional steady state, which can realize accurate liquid volume calculation well, and the overall metering error is maintained within 5%. Furthermore, validated by a series of laboratory calibration tests and multi-scenario field tests, the metering error of the developed device is consistently less than 10% under both indoor controlled conditions and actual complex on-site working conditions, which delivers a favorable and stable metering performance for the two–phase flow system. The proposed differential pressure double-tank alternating metering scheme in this study effectively reduces the interference of bubbles on liquid-phase metering accuracy, provides a reliable technical path for wellhead metering of produced fluid with high foam content, and also offers an effective solution for similar metering problems of foamy oil.

Authors

Institutions

Publication Details

Journal
Processes
Published
2026-11-16
DOI
https://doi.org/10.3390/pr14223685
Primary Topic
Flow Measurement and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Design and Performance Validation of Foam Oil Metering Separator

Xiaoqin Xiong, Z. Liu, Xiangshun Zeng, Yingting Sun et al.
2 links
Processes
Flow Measurement and Analysis
article

Design and Performance Validation of Foam Oil Metering Separator

Xiaoqin Xiong, Z. Liu, Xiangshun Zeng, Yingting Sun, Haifan Zhang, Tao LIAO
article en

Abstract

Aiming at the engineering problems of low metering accuracy and frequent tank overflow in conventional metering separators caused by the high foam content characteristics of produced fluid from CO2 flooding, this paper designs a differential pressure continuous metering separator with a double-tank configuration. By developing a coupled numerical framework that incorporates the Eulerian multiphase flow model, the Realizable k–ε turbulence model, the Luo population balance model (PBM), and a bubble attenuation model calibrated with field-sampled foam half-life and bubble size range, the effects of foam half–life, pressure, and temperature on the internal flow field characteristics and metering performance of a single metering tank are analyzed as an engineering sensitivity study. The overall metering performance of the actual six-tank alternating metering separator is validated by laboratory and field tests. The single-tank simulation results indicate that under the working conditions of high gas–liquid ratio, different foam half–lives, different operating pressures and different temperatures, after the gas, foam and crude oil enter the separator tank, the distribution of foam and crude oil is clearly stratified. The liquid column pressures of foam and crude oil in the single tank can quickly reach a regional steady state, which can realize accurate liquid volume calculation well, and the overall metering error is maintained within 5%. Furthermore, validated by a series of laboratory calibration tests and multi-scenario field tests, the metering error of the developed device is consistently less than 10% under both indoor controlled conditions and actual complex on-site working conditions, which delivers a favorable and stable metering performance for the two–phase flow system. The proposed differential pressure double-tank alternating metering scheme in this study effectively reduces the interference of bubbles on liquid-phase metering accuracy, provides a reliable technical path for wellhead metering of produced fluid with high foam content, and also offers an effective solution for similar metering problems of foamy oil.

ProcessesVol. 14(22)
Sinopec (China) (CN), China University of Petroleum, Beijing (CN), PetroChina Xinjiang Oilfield Company (China) (CN)
Natural Science Foundation of Xinjiang Province
Flow Measurement and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon