Exploratory Investigation on the Delay of Chloride Ion Penetration and Potential Rebar Protection in Concrete Using Direct Current Static Solenoid Magnetic Fields

Chloride-induced corrosion of embedded steel bars deteriorates reinforced concrete structures. This study investigated a static solenoid magnetic field (SSMF) as a means of chloride penetration delaying (CLPD). The SSMF was generated by a coil wound around a threaded steel bar embedded in concrete. Concrete cylinders were exposed to 10% sodium chloride solution for 45 days. 6 current levels were tested, from 0 to 1.0 A. Penetration was assessed via AgNO3 testing. A training-free feed-forward convolutional neural network quantified the affected area. In the specimens tested, the non-penetrated area ratio rose monotonically, from 41.41% at 0.0 A to 63.30% at 1.0 A. The increase followed a stepwise, non-linear trend. Lorentz-force and magnetohydrodynamic mechanisms were shown to be insufficient to explain this effect. Hydration shell perturbation coupled with pore-throat constrictivity is proposed as a candidate mechanism instead. These findings identify a previously undocumented phenomenon. SSMF exposure warrants further mechanistic and replicate investigation.

Authors

Institutions

Publication Details

Journal
Materials
Published
2026-11-16
DOI
https://doi.org/10.3390/ma19224849
Primary Topic
Concrete Corrosion and Durability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Exploratory Investigation on the Delay of Chloride Ion Penetration and Potential Rebar Protection in Concrete Using Direct Current Static Solenoid Magnetic Fields

Byeong-Hun Woo, Changhwan Jang, Ji-Hoon Cho, Hong-Gi Kim et al.
1 links
Materials
Concrete Corrosion and Durability
article

Exploratory Investigation on the Delay of Chloride Ion Penetration and Potential Rebar Protection in Concrete Using Direct Current Static Solenoid Magnetic Fields

Byeong-Hun Woo, Changhwan Jang, Ji-Hoon Cho, Hong-Gi Kim, Jin-Young Seok
article en

Abstract

Chloride-induced corrosion of embedded steel bars deteriorates reinforced concrete structures. This study investigated a static solenoid magnetic field (SSMF) as a means of chloride penetration delaying (CLPD). The SSMF was generated by a coil wound around a threaded steel bar embedded in concrete. Concrete cylinders were exposed to 10% sodium chloride solution for 45 days. 6 current levels were tested, from 0 to 1.0 A. Penetration was assessed via AgNO3 testing. A training-free feed-forward convolutional neural network quantified the affected area. In the specimens tested, the non-penetrated area ratio rose monotonically, from 41.41% at 0.0 A to 63.30% at 1.0 A. The increase followed a stepwise, non-linear trend. Lorentz-force and magnetohydrodynamic mechanisms were shown to be insufficient to explain this effect. Hydration shell perturbation coupled with pore-throat constrictivity is proposed as a candidate mechanism instead. These findings identify a previously undocumented phenomenon. SSMF exposure warrants further mechanistic and replicate investigation.

MaterialsVol. 19(22)
Korea Institute of Civil Engineering and Building Technology (KR), Daejin University (KR)
Industry, innovation and infrastructure
Concrete Corrosion and Durability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon