High dose-rate response and individual correction of commercial electronic personal dosimeters for nuclear emergency radiation protection

Reliable active dosimetry is essential during nuclear and radiological emergencies, yet the response of deployed electronic personal dosimeters (EPDs) is rarely verified for every unit in the 1– 7 S v h − 1 regime. Type testing establishes model-level compliance, whereas emergency use depends on individual instruments. We characterised ten commercial silicon-diode EPD units of the same IEC 61526-certified model in a traceable 137 Cs reference field. The units showed high repeatability ( 𝐶 ⁢ 𝑉 < 2 % ) but unit-dependent dose-rate bias, from −9.3% to +7.7% at 7 S v h − 1 ; one unit over-responded progressively, which a single dead-time correction cannot reproduce. A device-specific second-order polynomial correction reduced the mean RMSE from 0.187 to 0 . 0 1 1 S v h − 1 and held the residual instrumental non-linearity within ± 1 . 5 % . Applying the first-session coefficients to an independent second session, and predicting intermediate dose rates not used in fitting, both kept residuals within ± 1 . 5 % , confirming temporal reproducibility and out-of-sample validity. Bare-device directional measurements showed up to ≈ 1 9 % lateral response reduction, supporting an optional conservative planning margin ( 𝑆 ⁢ 𝐹 ≈ 1 . 2 ). All corrections were established for a single 137 Cs spectrum and must not be extrapolated to other photon energies without re-calibration. Individual pre-deployment characterisation is a practical complement to model-level type testing for EPDs in nuclear emergency radiation protection.

Authors

Institutions

Publication Details

Journal
Nuclear Engineering and Technology
Published
2026-11-16
DOI
https://doi.org/10.1016/j.net.2026.104811
Primary Topic
Radioactive Decay and Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

High dose-rate response and individual correction of commercial electronic personal dosimeters for nuclear emergency radiation protection

Jang-Oh Kim, Gyoungjun Choi, Ku Kang, Myeongsik Shin et al.
1 links
Nuclear Engineering and Technology
Radioactive Decay and Measurement Techniques
article

High dose-rate response and individual correction of commercial electronic personal dosimeters for nuclear emergency radiation protection

Jang-Oh Kim, Gyoungjun Choi, Ku Kang, Myeongsik Shin, Hyungwoo You, Wonseok Bak, Jun Yoo
article en

Abstract

Reliable active dosimetry is essential during nuclear and radiological emergencies, yet the response of deployed electronic personal dosimeters (EPDs) is rarely verified for every unit in the 1– 7 S v h − 1 regime. Type testing establishes model-level compliance, whereas emergency use depends on individual instruments. We characterised ten commercial silicon-diode EPD units of the same IEC 61526-certified model in a traceable 137 Cs reference field. The units showed high repeatability ( 𝐶 ⁢ 𝑉 < 2 % ) but unit-dependent dose-rate bias, from −9.3% to +7.7% at 7 S v h − 1 ; one unit over-responded progressively, which a single dead-time correction cannot reproduce. A device-specific second-order polynomial correction reduced the mean RMSE from 0.187 to 0 . 0 1 1 S v h − 1 and held the residual instrumental non-linearity within ± 1 . 5 % . Applying the first-session coefficients to an independent second session, and predicting intermediate dose rates not used in fitting, both kept residuals within ± 1 . 5 % , confirming temporal reproducibility and out-of-sample validity. Bare-device directional measurements showed up to ≈ 1 9 % lateral response reduction, supporting an optional conservative planning margin ( 𝑆 ⁢ 𝐹 ≈ 1 . 2 ). All corrections were established for a single 137 Cs spectrum and must not be extrapolated to other photon energies without re-calibration. Individual pre-deployment characterisation is a practical complement to model-level type testing for EPDs in nuclear emergency radiation protection.

Nuclear Engineering and TechnologyVol. 59(3)
Inje University (KR), Korea Atomic Energy Research Institute (KR)
Good health and well-being
Radioactive Decay and Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon