Alignment-independent analysis of full-arch digital implant impression workflows: an in vitro comparative study

Accurate impressions are critical for the clinical success of full‑arch implant-supported restorations. The aim of this in vitro study was to compare the accuracy of different digital implant impression workflows for complete-arch rehabilitation. A mandibular typodont with an All-on-4 implant configuration was fabricated. The model was digitized using TRIOS 5 (3shape, Copenhagen, Denmark) and Aoralscan Elite (Shining 3D; Hangzhou, China) intraoral scanners across five workflows: scanning with conventional vertical scanbodies (Intr_trios and Intr_shining), splinted scanbody scanning (Opti_trios and Opti_shining) and photogrammetry-assisted scanning (Intr_ptg). Deviations were assessed on multi-unit abutment-level inter-axis and inter-marker relationships, avoiding best-fit superimposition. Linear and angular deviations, as well as within-group variability, were analyzed. Overall linear discrepancy was 81.56 ± 41.60 μm (51.80–111.31) for Intr_Trios, 28.99 ± 12.21 μm (20.25–37.72) for Intr_Shining, 73.93 ± 31.57 μm (49.66–98.19) µm for Opti_trios, 57.88 ± 8.74 μm (51.63–64.13) for Opti_Shining and 36.93 ± 10.00 μm (29.78–44.09) for Intr_Ptg. Overall angular discrepancy was 1.178 ± 0.397° (0.894–1.462) for Intr_trios, 0.748 ± 0.365° (0.487–1.008) for Intr_shining, 1.159 ± 0.230° (0.982–1.336) for Opti_trios, 0.986 ± 0.054° (0.948–1.025) for Opti_shining and 0.614 ± 0.045° (0.582–0.647) for Intr_ptg. Photogrammetry-assisted intraoral scanning demonstrated superior angular accuracy and repeatability, while conventional scanbody workflows achieved the lowest linear deviations. Splinting did not consistently improve accuracy. Digital implant impression workflows should be selected according to the specific requirements of each full-arch rehabilitation case. Different digital implant impression workflows demonstrated distinct linear and angular accuracy profiles. Selecting the appropriate workflow for full-arch implant rehabilitation may improve prosthetic fit and reduce mechanical complications.

Authors

Institutions

Publication Details

Journal
BMC Oral Health
Published
2026-11-16
DOI
https://doi.org/10.1186/s12903-026-10444-w
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Alignment-independent analysis of full-arch digital implant impression workflows: an in vitro comparative study

Emese Ábrám, Attila Mühl, Péter Hermann, Judit Borbély et al.
2 links
BMC Oral Health
Dental Implant Techniques and Outcomes
article

Alignment-independent analysis of full-arch digital implant impression workflows: an in vitro comparative study

Emese Ábrám, Attila Mühl, Péter Hermann, Judit Borbély, Maria A. Loza, Barbara Kispélyi, Boldizsár Vánkos, Siwen Yang
article en

Abstract

Accurate impressions are critical for the clinical success of full‑arch implant-supported restorations. The aim of this in vitro study was to compare the accuracy of different digital implant impression workflows for complete-arch rehabilitation. A mandibular typodont with an All-on-4 implant configuration was fabricated. The model was digitized using TRIOS 5 (3shape, Copenhagen, Denmark) and Aoralscan Elite (Shining 3D; Hangzhou, China) intraoral scanners across five workflows: scanning with conventional vertical scanbodies (Intr_trios and Intr_shining), splinted scanbody scanning (Opti_trios and Opti_shining) and photogrammetry-assisted scanning (Intr_ptg). Deviations were assessed on multi-unit abutment-level inter-axis and inter-marker relationships, avoiding best-fit superimposition. Linear and angular deviations, as well as within-group variability, were analyzed. Overall linear discrepancy was 81.56 ± 41.60 μm (51.80–111.31) for Intr_Trios, 28.99 ± 12.21 μm (20.25–37.72) for Intr_Shining, 73.93 ± 31.57 μm (49.66–98.19) µm for Opti_trios, 57.88 ± 8.74 μm (51.63–64.13) for Opti_Shining and 36.93 ± 10.00 μm (29.78–44.09) for Intr_Ptg. Overall angular discrepancy was 1.178 ± 0.397° (0.894–1.462) for Intr_trios, 0.748 ± 0.365° (0.487–1.008) for Intr_shining, 1.159 ± 0.230° (0.982–1.336) for Opti_trios, 0.986 ± 0.054° (0.948–1.025) for Opti_shining and 0.614 ± 0.045° (0.582–0.647) for Intr_ptg. Photogrammetry-assisted intraoral scanning demonstrated superior angular accuracy and repeatability, while conventional scanbody workflows achieved the lowest linear deviations. Splinting did not consistently improve accuracy. Digital implant impression workflows should be selected according to the specific requirements of each full-arch rehabilitation case. Different digital implant impression workflows demonstrated distinct linear and angular accuracy profiles. Selecting the appropriate workflow for full-arch implant rehabilitation may improve prosthetic fit and reduce mechanical complications.

BMC Oral Health
Semmelweis University (HU), University of Pecs (HU), The University of Texas Health Science Center at Houston (US)
Good health and well-being
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon