Tissue-depth-calibrated triple-band antenna and signal pipeline for wearable five-analyte biosensing

Non-invasive wearable sensing of multiple physiological analytes is limited by microwave antenna detuning under wrist body-loading. Existing radio-frequency (RF) glucose-sensing antennas operate at a single frequency and rarely report quantified body-loading compensation. This work contributes two elements, both evaluated entirely in simulation. First, a triple-band microstrip patch antenna whose operating frequencies at 2.45, 5.8, and 8.5 GHz are selected from the electromagnetic penetration depth into distinct wrist tissue compartments rather than from communication band allocation. The selection is derived from the Cole-Cole dispersion of the tissue composite and cross-validated between independent finite-element and finite-difference solvers. Active PIN (positive-intrinsic-negative) diode matching restores the reflection coefficient lost to body-loading at the shortest penetration depth, where glucose permittivity sensitivity is highest. Second, a four-stage signal pipeline coupling sigmoid-weighted recursive least-squares (RLS) motion rejection, cross-modal feature extraction, a normalised seven-state Kalman observer, and INT8-quantised gradient-boosted inference on an ARM Cortex-M33 processor, with each stage isolated by ablation. Evaluation across 1,000 Dalla Man Monte Carlo virtual subjects yielded a simulation-derived glucose reconstruction mean absolute relative difference (MARD) of 9.3% within the synthetic Dalla Man/forward-simulation framework on 200 held-out subjects. Simulation-based Clarke Error Grid analysis placed 91.3% of estimates in Zone A. All reported figures quantify inversion fidelity within the generating pipeline, not ISO 15197:2013-certified clinical accuracy. No hardware was fabricated and no human data were used.

Authors

Institutions

Publication Details

Journal
Discover Applied Sciences
Published
2026-11-16
DOI
https://doi.org/10.1007/s42452-026-09909-y
Primary Topic
Microwave Imaging and Scattering Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Tissue-depth-calibrated triple-band antenna and signal pipeline for wearable five-analyte biosensing

Praween Kumar Nishad
4 links
Discover Applied Sciences
Microwave Imaging and Scattering Analysis
article

Tissue-depth-calibrated triple-band antenna and signal pipeline for wearable five-analyte biosensing

Praween Kumar Nishad
article en

Abstract

Non-invasive wearable sensing of multiple physiological analytes is limited by microwave antenna detuning under wrist body-loading. Existing radio-frequency (RF) glucose-sensing antennas operate at a single frequency and rarely report quantified body-loading compensation. This work contributes two elements, both evaluated entirely in simulation. First, a triple-band microstrip patch antenna whose operating frequencies at 2.45, 5.8, and 8.5 GHz are selected from the electromagnetic penetration depth into distinct wrist tissue compartments rather than from communication band allocation. The selection is derived from the Cole-Cole dispersion of the tissue composite and cross-validated between independent finite-element and finite-difference solvers. Active PIN (positive-intrinsic-negative) diode matching restores the reflection coefficient lost to body-loading at the shortest penetration depth, where glucose permittivity sensitivity is highest. Second, a four-stage signal pipeline coupling sigmoid-weighted recursive least-squares (RLS) motion rejection, cross-modal feature extraction, a normalised seven-state Kalman observer, and INT8-quantised gradient-boosted inference on an ARM Cortex-M33 processor, with each stage isolated by ablation. Evaluation across 1,000 Dalla Man Monte Carlo virtual subjects yielded a simulation-derived glucose reconstruction mean absolute relative difference (MARD) of 9.3% within the synthetic Dalla Man/forward-simulation framework on 200 held-out subjects. Simulation-based Clarke Error Grid analysis placed 91.3% of estimates in Zone A. All reported figures quantify inversion fidelity within the generating pipeline, not ISO 15197:2013-certified clinical accuracy. No hardware was fabricated and no human data were used.

Discover Applied Sciences
Symbiosis International University (IN)
Good health and well-being
Microwave Imaging and Scattering Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon