A low-cost direct-conversion CZT gamma camera for planar thyroid scintigraphy: detector characterisation and clinical demonstration against a commercial NaI(Tl) system

Abstract Direct-conversion cadmium zinc telluride (CZT) detectors have well-documented advantages over the sodium iodide (NaI(Tl))/photomultiplier cameras still standard in clinical gamma imaging, but low-cost, indigenously developed CZT systems are seldom characterised in detail. We characterise the detector physics of one such camera, a portable Small Area Imaging Gamma Camera (SAIGC; 44×44 pixellated CZT array, 2×2×5 mm elements, 88×88 mm field of view), and benchmark it against a commercial GE Infinia NaI(Tl) system for planar thyroid scintigraphy. Thirty patients referred for ⁹⁹ᵐTc-pertechnetate scintigraphy were imaged on both systems, with every SAIGC figure derived from raw list-mode data and compared with the published NEMA NU-1 specifications of GE Infinia. Energy resolution was 3.52% full width at half maximum at 140 keV, against 9.8% for GE Infinia. Separately, clinical pixel counts followed Poisson statistics on short timescales, with no detectable correlated counting from the electronics. Median acquisition time was 119.6 s per view. Bench source and phantom studies showed spatial discrimination, simultaneous dual-isotope imaging (¹⁵²Eu/⁹⁹ᵐTc, only 18 keV apart) and thyroid morphology preserved over a full 0–360° n, indicating single-photon emission computed tomography (SPECT) feasibility. The camera delivers these detector-level gains, alongside clinically interpretable images, at roughly one-tenth the cost.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-16
DOI
https://doi.org/10.21203/rs.3.rs-11529171/v1
Primary Topic
Radiation Detection and Scintillator Technologies
Type
preprint

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

A low-cost direct-conversion CZT gamma camera for planar thyroid scintigraphy: detector characterisation and clinical demonstration against a commercial NaI(Tl) system

Murali Ravi, Vishal Rao, Koushik V
1 links
Research Square
Radiation Detection and Scintillator Technologies
preprint

A low-cost direct-conversion CZT gamma camera for planar thyroid scintigraphy: detector characterisation and clinical demonstration against a commercial NaI(Tl) system

Murali Ravi, Vishal Rao, Koushik V
preprint en

Abstract

Abstract Direct-conversion cadmium zinc telluride (CZT) detectors have well-documented advantages over the sodium iodide (NaI(Tl))/photomultiplier cameras still standard in clinical gamma imaging, but low-cost, indigenously developed CZT systems are seldom characterised in detail. We characterise the detector physics of one such camera, a portable Small Area Imaging Gamma Camera (SAIGC; 44×44 pixellated CZT array, 2×2×5 mm elements, 88×88 mm field of view), and benchmark it against a commercial GE Infinia NaI(Tl) system for planar thyroid scintigraphy. Thirty patients referred for ⁹⁹ᵐTc-pertechnetate scintigraphy were imaged on both systems, with every SAIGC figure derived from raw list-mode data and compared with the published NEMA NU-1 specifications of GE Infinia. Energy resolution was 3.52% full width at half maximum at 140 keV, against 9.8% for GE Infinia. Separately, clinical pixel counts followed Poisson statistics on short timescales, with no detectable correlated counting from the electronics. Median acquisition time was 119.6 s per view. Bench source and phantom studies showed spatial discrimination, simultaneous dual-isotope imaging (¹⁵²Eu/⁹⁹ᵐTc, only 18 keV apart) and thyroid morphology preserved over a full 0–360° n, indicating single-photon emission computed tomography (SPECT) feasibility. The camera delivers these detector-level gains, alongside clinically interpretable images, at roughly one-tenth the cost.

Research Square
HCG Cancer Centre (IN), Sri Sathya Sai Institute of Higher Learning (IN)
Department of Science and Technology, Ministry of Science and Technology, India
Good health and well-being
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon