Validation of diffusive samplers for the simultaneous measurement of nitrogen oxides

Abstract. Poor air quality is a major threat to human and ecosystem health, and policies aimed at abating air pollution rely on ambient monitoring to apportion sources, validate inventories and assess the efficacy of interventions. Nitrogen oxides (NOx ≡ NO + NO2) are key air quality pollutants and their monitoring relies on complex and resource-intensive reference instrumentation. Diffusive samplers offer a cost-effective way to monitor NOx across entire localities, overcoming some of the limitations of reference instruments. This study determined the diffusive sampling rates of three types of commercially available samplers (Passam AG's NO2 and NOx samplers, Gradko International's NO2 samplers) and one currently under development (Gradko's NOx samplers). Samplers were exposed monthly at an air quality monitoring station in central London from November 2022 to February 2025. In addition, laboratory exposures of the same sampler types were performed in the Controlled Atmosphere Test Facility (CATFAC). During all exposures, samplers were co-located with reference analysers providing traceable NOx concentrations. After exposure the samplers were returned to the respective manufacturers for chemical analysis, and the reported nitrite results were combined with the reference data and exposure times to determine the experimental NO and NO2 diffusive sampling rates, UNO and UNO2 respectively. Measured diffusive sampling rates at standard conditions (T = 20 °C and p = 101.3 kPa) for the Passam samplers were UNO = (5.67 ± 0.20) × 10−5 m3 h−1 and UNO2 = (4.73 ± 0.11) × 10−5 m3 h−1. The sampling rate for the new design of the Gradko NO2 sampler (prepared with a 50 % TEA/acetone coating) was UNO2 = (6.80 ± 0.14) × 10−5 m3 h−1, consistent with that from an earlier design (with 20 % TEA/H2O coating) and indicating that different sorbent recipe had no measurable effect on . UNO for the Gradko samplers was UNO = (1.92 ± 0.20) × 10−5 m3 h−1, below the value expected from molecular diffusivities. Further tests indicated that the oxidant formulation in the Gradko NOx samplers required further optimisation to achieve quantitative conversion of NO to NO2 throughout the exposure period. Storage tests were carried out to establish the effects of time on the extracted nitrite, and indicated good stability of the adsorbed nitrite over timescales of 2–3 months. Analysis of environmental influences showed no significant temperature dependence after normalisation to standard conditions, while evidence was found for minor effects associated with ozone concentrations and high analyte loadings. This work provides traceable validation of diffusive samplers for the simultaneous measurement of NO and NO2 and demonstrates their potential to deliver spatially resolved NOx data for air quality assessment, emissions inventory verification and atmospheric model evaluation.

Authors

Institutions

Publication Details

Published
2026-11-16
DOI
https://doi.org/10.5194/egusphere-2026-5280
Primary Topic
Air Quality Monitoring and Forecasting
Type
preprint

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Validation of diffusive samplers for the simultaneous measurement of nitrogen oxides

Valerio Ferracci, Nicholas A. Martin, David C. Green, Anja H. Tremper et al.
Air Quality Monitoring and Forecasting
preprint

Validation of diffusive samplers for the simultaneous measurement of nitrogen oxides

Valerio Ferracci, Nicholas A. Martin, David C. Green, Anja H. Tremper, Linda Gates, Benjamin Michen, Yassine Wakim, Yaser Showman, Erin Cackett, Thomas G. Holmes
preprint en

Abstract

Abstract. Poor air quality is a major threat to human and ecosystem health, and policies aimed at abating air pollution rely on ambient monitoring to apportion sources, validate inventories and assess the efficacy of interventions. Nitrogen oxides (NOx ≡ NO + NO2) are key air quality pollutants and their monitoring relies on complex and resource-intensive reference instrumentation. Diffusive samplers offer a cost-effective way to monitor NOx across entire localities, overcoming some of the limitations of reference instruments. This study determined the diffusive sampling rates of three types of commercially available samplers (Passam AG's NO2 and NOx samplers, Gradko International's NO2 samplers) and one currently under development (Gradko's NOx samplers). Samplers were exposed monthly at an air quality monitoring station in central London from November 2022 to February 2025. In addition, laboratory exposures of the same sampler types were performed in the Controlled Atmosphere Test Facility (CATFAC). During all exposures, samplers were co-located with reference analysers providing traceable NOx concentrations. After exposure the samplers were returned to the respective manufacturers for chemical analysis, and the reported nitrite results were combined with the reference data and exposure times to determine the experimental NO and NO2 diffusive sampling rates, UNO and UNO2 respectively. Measured diffusive sampling rates at standard conditions (T = 20 °C and p = 101.3 kPa) for the Passam samplers were UNO = (5.67 ± 0.20) × 10−5 m3 h−1 and UNO2 = (4.73 ± 0.11) × 10−5 m3 h−1. The sampling rate for the new design of the Gradko NO2 sampler (prepared with a 50 % TEA/acetone coating) was UNO2 = (6.80 ± 0.14) × 10−5 m3 h−1, consistent with that from an earlier design (with 20 % TEA/H2O coating) and indicating that different sorbent recipe had no measurable effect on . UNO for the Gradko samplers was UNO = (1.92 ± 0.20) × 10−5 m3 h−1, below the value expected from molecular diffusivities. Further tests indicated that the oxidant formulation in the Gradko NOx samplers required further optimisation to achieve quantitative conversion of NO to NO2 throughout the exposure period. Storage tests were carried out to establish the effects of time on the extracted nitrite, and indicated good stability of the adsorbed nitrite over timescales of 2–3 months. Analysis of environmental influences showed no significant temperature dependence after normalisation to standard conditions, while evidence was found for minor effects associated with ozone concentrations and high analyte loadings. This work provides traceable validation of diffusive samplers for the simultaneous measurement of NO and NO2 and demonstrates their potential to deliver spatially resolved NOx data for air quality assessment, emissions inventory verification and atmospheric model evaluation.

National Physical Laboratory (GB), Imperial College London (GB)
Department for Environment, Food and Rural Affairs, UK Government, Department for Science, Innovation and Technology
Air Quality Monitoring and Forecasting
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon