Enhancing multimodal brain image registration via ultrasound mathematical modeling

Ultrasound is a fast, widely available, and cost-effective imaging modality. These properties make it well-suited for intra-operative use, where it can provide surgeons with near real-time updated visualization of anatomical structures and tissue deformations. In brain tumor resection, this capability is especially valuable due to the delicate nature of the operation and presence of brain shift. A common strategy to exploit intra-operative ultrasound is to register pre-operative images, typically high-resolution MRI, to intra-operative ultrasound, thereby combining detailed anatomical information with up-to-date deformation estimates. In this work, we present three registration methods based on distinct models of the relationship between ultrasound intensity and the intensities of other imaging modalities. At the core of each method is a similarity metric, derived within a unified analytical framework. We evaluate these methods using rigid and nonlinear deformation models across six neurosurgical registration tasks: three involving pre-resection ultrasound volumes, which are well studied in the literature, and three involving post-resection ultrasound volumes, a setting that has received limited attention in prior work. Averaged over all datasets, our proposed methods reduce the target registration error from 5.49 mm to 2.96 mm, 2.85 mm, and 3.07 mm, respectively. Using a single, fixed set of parameters, our approaches consistently improve accuracy across all tasks, with total runtimes below 40 s and performances comparable to state-of-the-art methods. Finally, we demonstrate how different assumptions about ultrasound intensity formation influence registration performance and identify the models that lead to more accurate and robust alignment.

Authors

Institutions

Publication Details

Journal
Biomedical Signal Processing and Control
Published
2026-11-16
DOI
https://doi.org/10.1016/j.bspc.2026.111744
Primary Topic
Medical Image Segmentation Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Enhancing multimodal brain image registration via ultrasound mathematical modeling

Eskandari Mohammadreza, D. Louis Collins, Raphaël Christin
Biomedical Signal Processing and Control
Medical Image Segmentation Techniques
article

Enhancing multimodal brain image registration via ultrasound mathematical modeling

Eskandari Mohammadreza, D. Louis Collins, Raphaël Christin
article en

Abstract

Ultrasound is a fast, widely available, and cost-effective imaging modality. These properties make it well-suited for intra-operative use, where it can provide surgeons with near real-time updated visualization of anatomical structures and tissue deformations. In brain tumor resection, this capability is especially valuable due to the delicate nature of the operation and presence of brain shift. A common strategy to exploit intra-operative ultrasound is to register pre-operative images, typically high-resolution MRI, to intra-operative ultrasound, thereby combining detailed anatomical information with up-to-date deformation estimates. In this work, we present three registration methods based on distinct models of the relationship between ultrasound intensity and the intensities of other imaging modalities. At the core of each method is a similarity metric, derived within a unified analytical framework. We evaluate these methods using rigid and nonlinear deformation models across six neurosurgical registration tasks: three involving pre-resection ultrasound volumes, which are well studied in the literature, and three involving post-resection ultrasound volumes, a setting that has received limited attention in prior work. Averaged over all datasets, our proposed methods reduce the target registration error from 5.49 mm to 2.96 mm, 2.85 mm, and 3.07 mm, respectively. Using a single, fixed set of parameters, our approaches consistently improve accuracy across all tasks, with total runtimes below 40 s and performances comparable to state-of-the-art methods. Finally, we demonstrate how different assumptions about ultrasound intensity formation influence registration performance and identify the models that lead to more accurate and robust alignment.

Biomedical Signal Processing and ControlVol. 131
McGill University (CA)
Institute of Cancer Research
Good health and well-being
Medical Image Segmentation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon