Modeling and Applicability of Nonlinear RDDS for Controlled Closing of 550 kV SF6 Circuit Breakers

In the controlled closing of high voltage circuit breakers, the electrical making instant depends on how dielectric strength changes as the contacts approach. For a 550 kV SF6 circuit breaker, scaled contact breakdown tests were conducted to investigate the variation of breakdown voltage with gap distance, while electric field calculations were used to determine the dielectric strength characteristic of the actual interrupter. This characteristic was combined with 50 measured closing trajectories to analyze the rate of decay of dielectric strength (RDDS). Constant, piecewise linear and nonlinear RDDS models were calibrated using phase scan data and evaluated against 17 independent rated 90° closing records without refitting. The results show that spatial variation in dielectric strength has a much greater influence on the calculated RDDS characteristic than variation in closing speed. Relative to the calculated reference, spatial linearization produced a voltage RMSE of 170.21 kV, compared with 3.85 kV when measured motion was replaced by constant speed. Under the healthy contact condition, the three calibrated models gave a maximum difference of approximately 0.11 ms in the calculated mechanical closing targets, although their voltage and time prediction errors showed different rankings. Comparisons across four contact erosion states showed that calculated targets for S0 and S1 were unchanged across the four tested continuation rules, whereas S2 and S3 targets and some peak-closing method selections depended on the extrapolation assumption. The results indicate that RDDS model selection should account for contact condition, operating range, data coverage, and extrapolation assumptions rather than fitting accuracy alone.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-11-16
DOI
https://doi.org/10.3390/en19225509
Primary Topic
Vacuum and Plasma Arcs
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Modeling and Applicability of Nonlinear RDDS for Controlled Closing of 550 kV SF6 Circuit Breakers

Dehua Xiong, Minfu Liao, Xiongying Duan
1 links
Energies
Vacuum and Plasma Arcs
article

Modeling and Applicability of Nonlinear RDDS for Controlled Closing of 550 kV SF6 Circuit Breakers

Dehua Xiong, Minfu Liao, Xiongying Duan
article en

Abstract

In the controlled closing of high voltage circuit breakers, the electrical making instant depends on how dielectric strength changes as the contacts approach. For a 550 kV SF6 circuit breaker, scaled contact breakdown tests were conducted to investigate the variation of breakdown voltage with gap distance, while electric field calculations were used to determine the dielectric strength characteristic of the actual interrupter. This characteristic was combined with 50 measured closing trajectories to analyze the rate of decay of dielectric strength (RDDS). Constant, piecewise linear and nonlinear RDDS models were calibrated using phase scan data and evaluated against 17 independent rated 90° closing records without refitting. The results show that spatial variation in dielectric strength has a much greater influence on the calculated RDDS characteristic than variation in closing speed. Relative to the calculated reference, spatial linearization produced a voltage RMSE of 170.21 kV, compared with 3.85 kV when measured motion was replaced by constant speed. Under the healthy contact condition, the three calibrated models gave a maximum difference of approximately 0.11 ms in the calculated mechanical closing targets, although their voltage and time prediction errors showed different rankings. Comparisons across four contact erosion states showed that calculated targets for S0 and S1 were unchanged across the four tested continuation rules, whereas S2 and S3 targets and some peak-closing method selections depended on the extrapolation assumption. The results indicate that RDDS model selection should account for contact condition, operating range, data coverage, and extrapolation assumptions rather than fitting accuracy alone.

EnergiesVol. 19(22)
Dalian University of Technology (CN)
Fundamental Research Funds for the Central Universities
Vacuum and Plasma Arcs
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon