Comparison of 12-Month Visual Outcomes and Patient-Reported Measures between the BVI Isopure Enhanced Monofocal IOL and the AcrySof IQ Monofocal IOL
Purpose: To compare 12-month visual, refractive, and patient-reported outcomes between the BVI Isopure enhanced monofocal intraocular lens (IOL) and the AcrySof IQ monofocal IOL after cataract surgery. Methods: This retrospective comparative study included 40 eyes implanted with either BVI Isopure or AcrySof IQ. Outcomes at 1 and 12 months included visual acuity, refractive outcomes, distance-corrected defocus curves, dysphotopsia, spectacle dependence, and patient satisfaction; contrast sensitivity was evaluated at 1 month only. Continuous eye-level outcomes were primarily analyzed using linear mixed-effects models accounting for inter-eye correlation, whereas defocus curves were presented descriptively and patient-reported outcomes were analyzed at the patient level. Results: Sixteen BVI Isopure eyes and 24 AcrySof IQ eyes were analyzed. Defocus curves showed a numerical tendency toward better intermediate performance with BVI Isopure. BVI Isopure showed significantly lower patient-reported spectacle dependence for near, intermediate, and distance vision at 1 month and for near vision at 12 months, whereas AcrySof IQ showed significantly higher mesopic contrast sensitivity without glare at 6, 12, and 18 cycles/degree. No statistically significant between-group differences were observed in distance visual acuity or refractive predictability at either time point. Contrast sensitivity did not differ significantly under photopic without-glare or mesopic-with-glare conditions, and dysphotopsia scores and patient satisfaction did not differ significantly between groups. Conclusions: BVI Isopure showed lower patient-reported spectacle dependence at selected distances and time points, whereas AcrySof IQ showed higher mesopic contrast sensitivity without glare at several spatial frequencies. Defocus curves also showed a numerical tendency toward better intermediate performance with BVI Isopure. These exploratory findings warrant confirmation in larger, adequately powered prospective studies.
Authors
- Dong Hui Lim (ORCID: https://orcid.org/0000-0003-1543-7961)
- Seul Gi Lim
Institutions
- Samsung Medical Center (KR)
- Sungkyunkwan University (KR)
Publication Details
- Journal
- Korean Journal of Ophthalmology
- Published
- 2026-11-16
- DOI
- https://doi.org/10.3341/kjo.2026.0076
- Primary Topic
- Intraocular Surgery and Lenses
- Type
- article
- Field-Weighted Citation Impact
- 0.00