Signature-driven multimodal and physics-informed diagnosis of corrosion in automotive radiators

Abstract Automotive radiators are critical heat-rejection components whose corrosion compromises leak-tightness, heat-transfer efficiency and reliability. Their compact aluminium-based, multi-interface architecture promotes coupled internal and external degradation, with signatures often hidden, indirect or confounded by fouling and residues, limiting conventional inspection. This review integrates radiator architecture, exposure conditions, degradation mechanisms, observable signatures, diagnostic approaches and industrial transferability within a unified corrosion-diagnosis framework. A PRISMA-guided workflow screened Scopus and Web of Science records published from January 2016 to 15 April 2026 using eligibility screening and full-text assessment. The synthesis evaluated corrosion mechanisms, diagnostic targets, data modalities, validation evidence and deployment constraints. The evidence indicates a shift from corrosion description toward monitoring, sensing, AI-assisted assessment and multimodal diagnosis. Corrosion initiation and observability are governed mainly by radiator geometry, brazed interfaces, sacrificial layers, coolant chemistry, wet-dry salt exposure and flow heterogeneity. Internal degradation produces coolant, pressure or thermal disturbances, whereas external corrosion yields visual, thermal or blockage-related signatures. Failure-relevant signals remain poorly accessible in tube interiors, headers and buried joints. Conventional inspection is deployable but surface-biased, while NDT, sensing, thermo-hydraulic analysis and computer vision improve observability but remain target-specific and confounded. Validation is limited by scarce ground truth, non-representative datasets, domain shift and deployment constraints. Reliable diagnosis requires linking mechanisms, signatures, measurements, models and decisions. Progress depends on multimodal, physics-informed inference, realistic validation, standardized acquisition and uncertainty-aware deployment.

Authors

Institutions

Publication Details

Journal
Discover Materials
Published
2026-11-16
DOI
https://doi.org/10.1007/s43939-026-01060-0
Primary Topic
Corrosion Behavior and Inhibition
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Signature-driven multimodal and physics-informed diagnosis of corrosion in automotive radiators

Jamal Bouchnaif, Abdellah El Barkany, Faouaz Jeffali, Hamza Zarhyoun
1 links
Discover Materials
Corrosion Behavior and Inhibition
article

Signature-driven multimodal and physics-informed diagnosis of corrosion in automotive radiators

Jamal Bouchnaif, Abdellah El Barkany, Faouaz Jeffali, Hamza Zarhyoun
article en

Abstract

Abstract Automotive radiators are critical heat-rejection components whose corrosion compromises leak-tightness, heat-transfer efficiency and reliability. Their compact aluminium-based, multi-interface architecture promotes coupled internal and external degradation, with signatures often hidden, indirect or confounded by fouling and residues, limiting conventional inspection. This review integrates radiator architecture, exposure conditions, degradation mechanisms, observable signatures, diagnostic approaches and industrial transferability within a unified corrosion-diagnosis framework. A PRISMA-guided workflow screened Scopus and Web of Science records published from January 2016 to 15 April 2026 using eligibility screening and full-text assessment. The synthesis evaluated corrosion mechanisms, diagnostic targets, data modalities, validation evidence and deployment constraints. The evidence indicates a shift from corrosion description toward monitoring, sensing, AI-assisted assessment and multimodal diagnosis. Corrosion initiation and observability are governed mainly by radiator geometry, brazed interfaces, sacrificial layers, coolant chemistry, wet-dry salt exposure and flow heterogeneity. Internal degradation produces coolant, pressure or thermal disturbances, whereas external corrosion yields visual, thermal or blockage-related signatures. Failure-relevant signals remain poorly accessible in tube interiors, headers and buried joints. Conventional inspection is deployable but surface-biased, while NDT, sensing, thermo-hydraulic analysis and computer vision improve observability but remain target-specific and confounded. Validation is limited by scarce ground truth, non-representative datasets, domain shift and deployment constraints. Reliable diagnosis requires linking mechanisms, signatures, measurements, models and decisions. Progress depends on multimodal, physics-informed inference, realistic validation, standardized acquisition and uncertainty-aware deployment.

Discover Materials
Mohamed I University (MA), Sidi Mohamed Ben Abdellah University (MA)
Corrosion Behavior and Inhibition
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon