Optimal grid-forming distributed generation allocation and sizing in radial islanded microgrids under single-feeder contingencies: A loadability-driven approach

The transition from passive distribution systems to actively managed microgrids requires planning frameworks that account for islanded operation under network contingencies. In radial microgrids with inverter-interfaced, droop-controlled distributed generation units (DGs), a single-feeder outage partitions the system into two islands with different generation and load compositions. Under these conditions, DG allocation and sizing, combined with priority-driven load shedding, determine the loadability and curtailment needed to satisfy voltage, frequency, and line-current limits. This paper develops a loadability-driven planning framework for islanded radial microgrids that minimizes the total priority-weighted load shed across all single-feeder contingencies. The planning problem is formulated as a double-stage mixed-integer nonlinear program (MINLP). The outer stage selects DG locations and discrete ratings under a fixed capacity budget using a bound-guided search, while the inner stage determines priority-level loadability factors for each island through deterministic droop-based nonlinear power-flow (NLPF) evaluations subject to DG capability, voltage, frequency, and line-current constraints, with voltage- and frequency-dependent loads. On the IEEE 33-bus microgrid, the selected layout fully serves high-priority loads in all single-feeder contingencies and requires shedding in only two contingencies, with a weighted shedding objective of 0.2013 pu. Under a common NLPF evaluation, it reduces weighted shedding by 91% relative to a layout selected by mixed-integer second-order cone programming (MISOCP), while maintaining operational constraints on voltages, frequency, and line ampacity. Additional studies on droop representation, installed capacity, DG spatial distribution, load prioritization, loss-oriented planning, DG firm-capacity availability, and 141-bus scalability examine the effectiveness and practicality of the proposed contingency-driven planning framework.

Authors

Institutions

Publication Details

Journal
Applied Energy
Published
2026-11-16
DOI
https://doi.org/10.1016/j.apenergy.2026.129256
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Optimal grid-forming distributed generation allocation and sizing in radial islanded microgrids under single-feeder contingencies: A loadability-driven approach

Ehab Fahmy El-Saadany, Hatem Hussein Zeineldin, Khaled Ali Al Jaafari, Nour M. Shabar
1 links
Applied Energy
Microgrid Control and Optimization
article

Optimal grid-forming distributed generation allocation and sizing in radial islanded microgrids under single-feeder contingencies: A loadability-driven approach

Ehab Fahmy El-Saadany, Hatem Hussein Zeineldin, Khaled Ali Al Jaafari, Nour M. Shabar
article en

Abstract

The transition from passive distribution systems to actively managed microgrids requires planning frameworks that account for islanded operation under network contingencies. In radial microgrids with inverter-interfaced, droop-controlled distributed generation units (DGs), a single-feeder outage partitions the system into two islands with different generation and load compositions. Under these conditions, DG allocation and sizing, combined with priority-driven load shedding, determine the loadability and curtailment needed to satisfy voltage, frequency, and line-current limits. This paper develops a loadability-driven planning framework for islanded radial microgrids that minimizes the total priority-weighted load shed across all single-feeder contingencies. The planning problem is formulated as a double-stage mixed-integer nonlinear program (MINLP). The outer stage selects DG locations and discrete ratings under a fixed capacity budget using a bound-guided search, while the inner stage determines priority-level loadability factors for each island through deterministic droop-based nonlinear power-flow (NLPF) evaluations subject to DG capability, voltage, frequency, and line-current constraints, with voltage- and frequency-dependent loads. On the IEEE 33-bus microgrid, the selected layout fully serves high-priority loads in all single-feeder contingencies and requires shedding in only two contingencies, with a weighted shedding objective of 0.2013 pu. Under a common NLPF evaluation, it reduces weighted shedding by 91% relative to a layout selected by mixed-integer second-order cone programming (MISOCP), while maintaining operational constraints on voltages, frequency, and line ampacity. Additional studies on droop representation, installed capacity, DG spatial distribution, load prioritization, loss-oriented planning, DG firm-capacity availability, and 141-bus scalability examine the effectiveness and practicality of the proposed contingency-driven planning framework.

Applied EnergyVol. 427
Cairo University (EG), Khalifa University of Science and Technology (AE)
Khalifa University of Science, Technology and Research
Affordable and clean energy, Industry, innovation and infrastructure
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon