Refraction-aware calibration and rectification for accurate underwater stereo 3D reconstruction

Abstract Accurate underwater stereo 3D reconstruction remains challenging for sealed binocular cameras, because refraction through flat viewing windows violates the central projection and linear epipolar geometry assumptions underlying conventional calibration and rectification methods. This paper presents a refraction-aware calibration and rectification framework for underwater stereo 3D reconstruction. The framework adopts an explicit multilayer refraction model to represent the non-central imaging geometry caused by “air-glass-water” refraction. Based on this model, a two-stage air-water calibration strategy is developed, in which the intrinsic and stereo extrinsic parameters are calibrated in air, while the refraction-related parameters, including air-layer thicknesses and glass normal directions, are estimated underwater using multi-objective physical constraints. To enable accurate stereo matching, a depth-range-constrained rectification method is proposed to remap nonlinear refractive correspondence curves into approximately horizontal correspondences within the working range. The resulting disparities are then converted into metric underwater point clouds through refractive ray back-projection and closest-ray triangulation. Experiments were conducted using a self-developed sealed underwater binocular sensor on a water-tank platform. Standard ball-bar measurements and comparisons with structured-light reference scans were performed to assess reconstruction accuracy. Within the 400–600 mm working range, the standard ball-bar experiment achieved an average absolute length error of 0.9580 mm, while comparisons with structured-light reference scans yielded RMSE values of 0.8345 mm and 0.6022 mm for two anchor-chain components. These results demonstrate that the proposed framework provides an accurate geometric foundation for millimeter-level underwater stereo 3D reconstruction.

Authors

Institutions

Publication Details

Journal
Measurement Science and Technology
Published
2026-11-16
DOI
https://doi.org/10.1088/1361-6501/aec286
Primary Topic
Advanced Vision and Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Refraction-aware calibration and rectification for accurate underwater stereo 3D reconstruction

Wenpan Li, Wenlong Li, Rui Chen, Jinhua Zhang et al.
1 links
Measurement Science and Technology
Advanced Vision and Imaging
article

Refraction-aware calibration and rectification for accurate underwater stereo 3D reconstruction

Wenpan Li, Wenlong Li, Rui Chen, Jinhua Zhang, Yuqi Liu, Chao Gao
article en

Abstract

Abstract Accurate underwater stereo 3D reconstruction remains challenging for sealed binocular cameras, because refraction through flat viewing windows violates the central projection and linear epipolar geometry assumptions underlying conventional calibration and rectification methods. This paper presents a refraction-aware calibration and rectification framework for underwater stereo 3D reconstruction. The framework adopts an explicit multilayer refraction model to represent the non-central imaging geometry caused by “air-glass-water” refraction. Based on this model, a two-stage air-water calibration strategy is developed, in which the intrinsic and stereo extrinsic parameters are calibrated in air, while the refraction-related parameters, including air-layer thicknesses and glass normal directions, are estimated underwater using multi-objective physical constraints. To enable accurate stereo matching, a depth-range-constrained rectification method is proposed to remap nonlinear refractive correspondence curves into approximately horizontal correspondences within the working range. The resulting disparities are then converted into metric underwater point clouds through refractive ray back-projection and closest-ray triangulation. Experiments were conducted using a self-developed sealed underwater binocular sensor on a water-tank platform. Standard ball-bar measurements and comparisons with structured-light reference scans were performed to assess reconstruction accuracy. Within the 400–600 mm working range, the standard ball-bar experiment achieved an average absolute length error of 0.9580 mm, while comparisons with structured-light reference scans yielded RMSE values of 0.8345 mm and 0.6022 mm for two anchor-chain components. These results demonstrate that the proposed framework provides an accurate geometric foundation for millimeter-level underwater stereo 3D reconstruction.

Measurement Science and Technology
State Key Laboratory of Digital Manufacturing Equipment and Technology (CN), Huazhong University of Science and Technology (CN)
National Natural Science Foundation of China, National Major Science and Technology Projects of China
Advanced Vision and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon