Buffering an Island Grid with Stored Cold: A Thermal-Storage Coupled OTEC Plant Sized by Storage and Firming Budgets

A thermal plant charges insulated tanks with deep cold water and chilled return streams during low-demand hours, then discharges the stored cold through a second generating and cooling circuit to firm the island's evening peak, the coupling examined in the lines that follow. Its operating principle: cold-water thermal-storage coupled plant, where stored cold is stored energy: tanks of deep water let a steady thermal plant serve an unsteady grid. Headline values are cts surface temperature cts c = 27; cts deep temperature cts c = 5; cts temperature difference cts k = 22; cts carnot efficiency cts percent = 7.33; cts adopted cycle cts efficiency percent = 4.031; cts warm flow cts m3 per s cts = 45. The plant cannot hurry, but the grid keeps office hours; a tank of cold water is the translator between the two temperaments. SIMULATED, NOT MEASURED. Evening reliability for an island's homes is what the storage tanks buy. Grid firming is a utility function; the plant's stored cold serves peak-hour households, and the study assigns it no task beyond that service.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-16
DOI
https://doi.org/10.5281/zenodo.24291279
Primary Topic
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Buffering an Island Grid with Stored Cold: A Thermal-Storage Coupled OTEC Plant Sized by Storage and Firming Budgets

William Alexander Aldred
5 links
Zenodo (CERN European Organization for Nuclear Research)
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
article

Buffering an Island Grid with Stored Cold: A Thermal-Storage Coupled OTEC Plant Sized by Storage and Firming Budgets

William Alexander Aldred
article en

Abstract

A thermal plant charges insulated tanks with deep cold water and chilled return streams during low-demand hours, then discharges the stored cold through a second generating and cooling circuit to firm the island's evening peak, the coupling examined in the lines that follow. Its operating principle: cold-water thermal-storage coupled plant, where stored cold is stored energy: tanks of deep water let a steady thermal plant serve an unsteady grid. Headline values are cts surface temperature cts c = 27; cts deep temperature cts c = 5; cts temperature difference cts k = 22; cts carnot efficiency cts percent = 7.33; cts adopted cycle cts efficiency percent = 4.031; cts warm flow cts m3 per s cts = 45. The plant cannot hurry, but the grid keeps office hours; a tank of cold water is the translator between the two temperaments. SIMULATED, NOT MEASURED. Evening reliability for an island's homes is what the storage tanks buy. Grid firming is a utility function; the plant's stored cold serves peak-hour households, and the study assigns it no task beyond that service.

Zenodo (CERN European Organization for Nuclear Research)
Affordable and clean energy, Climate action, Industry, innovation and infrastructure
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon