Assessing Direct Greenhouse Gas Emissions in Ghana’s Thermal Power Sector Using Monte Carlo-Based Uncertainty Analysis

Ghana’s natural-gas-dominated power sector is the country’s largest source of energy-related CO2 emissions, yet uncertainty in direct (Scope 1) emissions remains understudied. In this work, we apply a Monte Carlo framework consistent with the 2006 IPCC Guidelines and 2019 Refinement to quantify uncertainty in CO2, CH4, N2O, and CO2-equivalent emissions from Ghana’s thermal plants from 2019 to 2024. Emissions were estimated with the IPCC Tier 1 method and default emission factors, and uncertainty was propagated with IPCC Approach 2 (Monte Carlo simulation, 105–106 draws). The uncertain inputs were activity data (±2%, IPCC default); the higher heating value (HHV) of the gas; and the CO2, CH4, and N2O emission factors, represented by normal, triangular, two-piece normal, and lognormal distributions. Emission-factor and activity-data errors were treated as systematic across plants and months. Cumulative CO2-equivalent emissions over the six-year period totaled 40.79 Mt (95% uncertainty interval, 39.20–42.53 Mt; ±4.1%), rising from 4.18 Mt in 2019 to 8.44 Mt in 2024 (a 102% increase), reflecting demand growth met largely by thermal generation. The activity data cover natural gas only; liquid fuels burned during gas shortfalls, mostly in 2019, were not recorded and could add 2–3 Mt over the period, so the rise from 2019 is overstated. One-at-a-time sensitivity analysis showed that the output variance is dominated by the CO2 emission factor (75.9%) and activity data (23.9%), with HHV contributing 0.2% and CH4 and N2O contributing <0.1% combined. A systematic error of ±10% in the fuel records would widen the interval to ±10.6%, making activity data the dominant source of uncertainty. To the best of the authors’ knowledge, this is the first IPCC Approach 2 uncertainty analysis of plant-level direct emissions from Ghana’s thermal power sector.

Authors

Institutions

Publication Details

Journal
Climate
Published
2026-11-16
DOI
https://doi.org/10.3390/cli14110252
Primary Topic
Renewable energy and sustainable power systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Assessing Direct Greenhouse Gas Emissions in Ghana’s Thermal Power Sector Using Monte Carlo-Based Uncertainty Analysis

Daniel Tutu Benefoh, Amos Tiereyangn Kabo-bah, Martin Kyereh Domfeh, Chrisentus Bangkewa Kuunifaa et al.
Climate
Renewable energy and sustainable power systems
article

Assessing Direct Greenhouse Gas Emissions in Ghana’s Thermal Power Sector Using Monte Carlo-Based Uncertainty Analysis

Daniel Tutu Benefoh, Amos Tiereyangn Kabo-bah, Martin Kyereh Domfeh, Chrisentus Bangkewa Kuunifaa, William Asamoah
article en

Abstract

Ghana’s natural-gas-dominated power sector is the country’s largest source of energy-related CO2 emissions, yet uncertainty in direct (Scope 1) emissions remains understudied. In this work, we apply a Monte Carlo framework consistent with the 2006 IPCC Guidelines and 2019 Refinement to quantify uncertainty in CO2, CH4, N2O, and CO2-equivalent emissions from Ghana’s thermal plants from 2019 to 2024. Emissions were estimated with the IPCC Tier 1 method and default emission factors, and uncertainty was propagated with IPCC Approach 2 (Monte Carlo simulation, 105–106 draws). The uncertain inputs were activity data (±2%, IPCC default); the higher heating value (HHV) of the gas; and the CO2, CH4, and N2O emission factors, represented by normal, triangular, two-piece normal, and lognormal distributions. Emission-factor and activity-data errors were treated as systematic across plants and months. Cumulative CO2-equivalent emissions over the six-year period totaled 40.79 Mt (95% uncertainty interval, 39.20–42.53 Mt; ±4.1%), rising from 4.18 Mt in 2019 to 8.44 Mt in 2024 (a 102% increase), reflecting demand growth met largely by thermal generation. The activity data cover natural gas only; liquid fuels burned during gas shortfalls, mostly in 2019, were not recorded and could add 2–3 Mt over the period, so the rise from 2019 is overstated. One-at-a-time sensitivity analysis showed that the output variance is dominated by the CO2 emission factor (75.9%) and activity data (23.9%), with HHV contributing 0.2% and CH4 and N2O contributing <0.1% combined. A systematic error of ±10% in the fuel records would widen the interval to ±10.6%, making activity data the dominant source of uncertainty. To the best of the authors’ knowledge, this is the first IPCC Approach 2 uncertainty analysis of plant-level direct emissions from Ghana’s thermal power sector.

ClimateVol. 14(11)
Environmental Protection Agency (GH), University of Energy and Natural Resources (GH)
Climate action, Affordable and clean energy
Renewable energy and sustainable power systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon