Experimental determination of liquid-phase heat transfer coefficient and gas-phase mass transfer coefficient ratio in a humidification column for air-water system

This study presents the experimental determination of the liquid-phase heat transfer coefficient and the gas-phase mass transfer coefficient ratio ( h L a/K y a ) based on Merkel's model. Experiments were conducted in a pilot-scale humidification tower packed with 8 mm × 8 mm Dixon rings and operated with both ambient and saturated air. The analysis shows that energy and moisture transfer are concentrated in the upper sections of the tower. Surface energy losses accounted for only 2% of the total transferred energy and were therefore neglected in subsequent calculations. Mean deviations of temperature between experimental and predicted air outlet conditions are 0.65 °C for ambient air to 6.62 °C for saturated air. Overall tower efficiencies ranged from 89 to 95% with ambient air and 96–99% with saturated air. The results contribute new experimental data for this packing configuration and support future design and optimization studies for humidification systems.

Authors

Institutions

Publication Details

Journal
Heliyon
Published
2026-11-16
DOI
https://doi.org/10.1016/j.heliyon.2026.e45724
Primary Topic
Adsorption and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Experimental determination of liquid-phase heat transfer coefficient and gas-phase mass transfer coefficient ratio in a humidification column for air-water system

Leda Pernett-Bolaño, Luis Obregón-Quiñones, Danny Sepúlveda-De Los Reyes
Heliyon
Adsorption and Cooling Systems
article

Experimental determination of liquid-phase heat transfer coefficient and gas-phase mass transfer coefficient ratio in a humidification column for air-water system

Leda Pernett-Bolaño, Luis Obregón-Quiñones, Danny Sepúlveda-De Los Reyes
article en

Abstract

This study presents the experimental determination of the liquid-phase heat transfer coefficient and the gas-phase mass transfer coefficient ratio ( h L a/K y a ) based on Merkel's model. Experiments were conducted in a pilot-scale humidification tower packed with 8 mm × 8 mm Dixon rings and operated with both ambient and saturated air. The analysis shows that energy and moisture transfer are concentrated in the upper sections of the tower. Surface energy losses accounted for only 2% of the total transferred energy and were therefore neglected in subsequent calculations. Mean deviations of temperature between experimental and predicted air outlet conditions are 0.65 °C for ambient air to 6.62 °C for saturated air. Overall tower efficiencies ranged from 89 to 95% with ambient air and 96–99% with saturated air. The results contribute new experimental data for this packing configuration and support future design and optimization studies for humidification systems.

HeliyonVol. 12(17)
Universidad del Atlántico (CO)
Universidad del Atlántico
Affordable and clean energy
Adsorption and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon