Development of a large‐animal model for dual‐lumen venopulmonary extracorporeal membrane oxygenation using right atrium‐to‐pulmonary artery cannulation

BACKGROUND: Venopulmonary extracorporeal membrane oxygenation (VP ECMO) using a right atrium-to-pulmonary artery configuration has emerged as an attractive strategy for right ventricular failure, bridge-to-lung transplantation, and selected cases of severe respiratory failure. Despite increasing clinical use of dual-lumen cannulas, dedicated large-animal models remain poorly described. We developed a reproducible swine model of VP ECMO using a dual-lumen right atrium-to-pulmonary artery cannula. METHODS: Twelve adult male Landrace pigs underwent attempted bedside cannulation through the right internal jugular vein. After ultrasound-guided vascular access, a pigtail catheter was advanced into the pulmonary artery under fluoroscopic guidance and exchanged for an ultra-stiff guidewire. A 29-Fr dual-lumen cannula was then positioned between the right atrium and pulmonary artery and connected to a centrifugal pump and membrane oxygenator. Animals were maintained on VP ECMO support for 12 h. RESULTS: Successful VP ECMO implantation was achieved in 8 of 12 animals (67%). Median maximal blood flow was 3.7 L/min (3.5-4.0). Median drainage and return pressures were -80 mmHg (-70 to -100) and 110 mmHg (100-122), respectively. Median pre-oxygenator venous oxygen saturation was 67% (65-75). Baseline pulmonary artery pressure was normal (20 mmHg [15-25]). Four procedures were unsuccessful, including three episodes of ventricular fibrillation and one cardiac tamponade. After refinement of the implantation technique, no clinically significant cannula migration or flow deterioration was observed during the 12-h observation period. CONCLUSIONS: This study establishes a reproducible large-animal model of dual-lumen VP ECMO suitable for procedural training, translational research, and future investigations.

Authors

Institutions

Publication Details

Journal
Animal Models and Experimental Medicine
Published
2026-11-16
DOI
https://doi.org/10.1002/ame2.70322
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Development of a large‐animal model for dual‐lumen venopulmonary extracorporeal membrane oxygenation using right atrium‐to‐pulmonary artery cannulation

Benjamin Péquignot, Erick Portocarrero, Bruno Lévy, Mickaël Lescroart et al.
2 links
Animal Models and Experimental Medicine
Mechanical Circulatory Support Devices
article

Development of a large‐animal model for dual‐lumen venopulmonary extracorporeal membrane oxygenation using right atrium‐to‐pulmonary artery cannulation

Benjamin Péquignot, Erick Portocarrero, Bruno Lévy, Mickaël Lescroart, Joël Nguyen, Guillaume Lebreton, Alma Revol
article en

Abstract

BACKGROUND: Venopulmonary extracorporeal membrane oxygenation (VP ECMO) using a right atrium-to-pulmonary artery configuration has emerged as an attractive strategy for right ventricular failure, bridge-to-lung transplantation, and selected cases of severe respiratory failure. Despite increasing clinical use of dual-lumen cannulas, dedicated large-animal models remain poorly described. We developed a reproducible swine model of VP ECMO using a dual-lumen right atrium-to-pulmonary artery cannula. METHODS: Twelve adult male Landrace pigs underwent attempted bedside cannulation through the right internal jugular vein. After ultrasound-guided vascular access, a pigtail catheter was advanced into the pulmonary artery under fluoroscopic guidance and exchanged for an ultra-stiff guidewire. A 29-Fr dual-lumen cannula was then positioned between the right atrium and pulmonary artery and connected to a centrifugal pump and membrane oxygenator. Animals were maintained on VP ECMO support for 12 h. RESULTS: Successful VP ECMO implantation was achieved in 8 of 12 animals (67%). Median maximal blood flow was 3.7 L/min (3.5-4.0). Median drainage and return pressures were -80 mmHg (-70 to -100) and 110 mmHg (100-122), respectively. Median pre-oxygenator venous oxygen saturation was 67% (65-75). Baseline pulmonary artery pressure was normal (20 mmHg [15-25]). Four procedures were unsuccessful, including three episodes of ventricular fibrillation and one cardiac tamponade. After refinement of the implantation technique, no clinically significant cannula migration or flow deterioration was observed during the 12-h observation period. CONCLUSIONS: This study establishes a reproducible large-animal model of dual-lumen VP ECMO suitable for procedural training, translational research, and future investigations.

Animal Models and Experimental Medicine
Inserm (FR), Sorbonne Université (FR), Assistance Publique – Hôpitaux de Paris (FR), Centre Hospitalier Régional et Universitaire de Nancy (FR), Centre Hospitalier Régional de Metz-Thionville (FR), Pitié-Salpêtrière Hospital (FR), Fondation pour l’innovation en Cadiométabolisme et Nutrition (FR), Défaillance Cardiovasculaire Aiguë et Chronique (FR), Université de Lorraine (FR)
Good health and well-being
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon