Investigating Deleterious Phases in a Flange of Superduplex UNS S32750 Superduplex Stainless Steel
Abstract This work investigates the severe pitting corrosion of a neck flange in the top side of an offshore platform. The chemical analysis revealed that the material is a stainless steel grade UNS S32750. The material suffered an incorrect heat treatment which resulted in a microstructure containing about 12.5% of deleterious phases ( σ and χ ) and only 3.9% of ferrite. The rapid deterioration of the external surface by pitting motivated the failure analysis and, fortunately, the flange didn’t present brittle fracture in service. The unproper microstructure was characterized by non-destructive (ferritoscope, hardness) and desctructive techniques (XRD, electrochemical anodic polarization, scanning electron microscopy). The corrosion properties could be regenerated by solution treatment at 1100 °C followed by water quenching. Instead, the flange was incorrectly treated at lower soaking temperature and/or slow cooling.
Authors
- B. L. da Silva
- S. S. M. Tavares
- A. R. Pimenta
- J. M. Pardal
- R. A. Roco Antunez
- G. Perez
Institutions
- Universidade Federal Fluminense (BR)
- Instituto Federal do Rio de Janeiro (BR)
Publication Details
- Journal
- Journal of Failure Analysis and Prevention
- Published
- 2026-11-16
- DOI
- https://doi.org/10.1007/s11668-026-02618-z
- Primary Topic
- Hydrogen embrittlement and corrosion behaviors in metals
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
- Conselho Nacional de Desenvolvimento Científico e Tecnológico
- Fundação Carlos Chagas Filho de Amparo à Pesquisa do Estado do Rio de Janeiro