Application of abdominal CT radiomic features for discriminating prevalent coronary heart disease in patients with type 2 diabetes mellitus

Purpose To develop and validate a hybrid model combining pancreatic-aortic radiomic features from non-contrast abdominal CT with clinical factors for discriminating prevalent coronary heart disease (CHD) status in patients with type 2 diabetes mellitus (T2DM). Materials and methods This retrospective study enrolled 407 T2DM patients (277 with CHD, 130 without), randomly split into training (n = 284) and internal test (n = 123) sets. Pancreatic auto-segmentation used a 3D V-Net, while the abdominal aortic wall was manually segmented by blinded radiologists. Following Image Biomarker Standardization Initiative (IBSI)-compliant preprocessing, radiomic features underwent reproducibility filtering, collinearity removal, LASSO regression and coefficient threshold filtering (|β|>0.05). Five models were built using logistic regression, support vector machine and Gaussian process classifiers. Model performance was assessed by AUC, calibration plots and decision-curve analysis (DCA). Results Seven pancreatic, nine aortic and three combined radiomic features were retained. The hybrid model yielded a numerically higher test-set AUC of 0.84 (95% CI: 0.77–0.91). Its discriminative performance was numerically greater than the clinical model (AUC = 0.65, 95% CI: 0.56–0.74; P < 0.001), pancreatic radiomic model (AUC = 0.70), aortic radiomic model (AUC = 0.82), and combined radiomic model (AUC = 0.83). It exhibited favorable calibration, with a net clinical benefit comparable to or numerically greater than the alternative models across threshold probabilities of 10%–90% on DCA. Conclusion The hybrid clinical-radiomic model improves discrimination of prevalent CHD status in T2DM patients, supporting opportunistic non-invasive identification of existing CHD using routine non-contrast abdominal CT.

Authors

Institutions

Publication Details

Journal
Frontiers in Endocrinology
Published
2026-11-16
DOI
https://doi.org/10.3389/fendo.2026.2006373
Primary Topic
Radiomics and Machine Learning in Medical Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Application of abdominal CT radiomic features for discriminating prevalent coronary heart disease in patients with type 2 diabetes mellitus

He Sui, Ming Qu, Xu Sun, Yingchun Wan et al.
4 links
Frontiers in Endocrinology
Radiomics and Machine Learning in Medical Imaging
article

Application of abdominal CT radiomic features for discriminating prevalent coronary heart disease in patients with type 2 diabetes mellitus

He Sui, Ming Qu, Xu Sun, Yingchun Wan, Tao Li, Zhanhao Mo, Yun Zhang, Lin Liu
article en

Abstract

Purpose To develop and validate a hybrid model combining pancreatic-aortic radiomic features from non-contrast abdominal CT with clinical factors for discriminating prevalent coronary heart disease (CHD) status in patients with type 2 diabetes mellitus (T2DM). Materials and methods This retrospective study enrolled 407 T2DM patients (277 with CHD, 130 without), randomly split into training (n = 284) and internal test (n = 123) sets. Pancreatic auto-segmentation used a 3D V-Net, while the abdominal aortic wall was manually segmented by blinded radiologists. Following Image Biomarker Standardization Initiative (IBSI)-compliant preprocessing, radiomic features underwent reproducibility filtering, collinearity removal, LASSO regression and coefficient threshold filtering (|β|>0.05). Five models were built using logistic regression, support vector machine and Gaussian process classifiers. Model performance was assessed by AUC, calibration plots and decision-curve analysis (DCA). Results Seven pancreatic, nine aortic and three combined radiomic features were retained. The hybrid model yielded a numerically higher test-set AUC of 0.84 (95% CI: 0.77–0.91). Its discriminative performance was numerically greater than the clinical model (AUC = 0.65, 95% CI: 0.56–0.74; P < 0.001), pancreatic radiomic model (AUC = 0.70), aortic radiomic model (AUC = 0.82), and combined radiomic model (AUC = 0.83). It exhibited favorable calibration, with a net clinical benefit comparable to or numerically greater than the alternative models across threshold probabilities of 10%–90% on DCA. Conclusion The hybrid clinical-radiomic model improves discrimination of prevalent CHD status in T2DM patients, supporting opportunistic non-invasive identification of existing CHD using routine non-contrast abdominal CT.

Frontiers in EndocrinologyVol. 17
Jilin University (CN), Weifang People's Hospital (CN), Second Affiliated Hospital of Jilin University (CN)
Good health and well-being
Radiomics and Machine Learning in Medical Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon