Preoperative infection-related laboratory documentation and recorded marker reactivity in ophthalmic procedures at a Somali referral hospital: a retrospective cross-sectional study

Abstract Background Reliable preoperative laboratory records require clear test identification, interpretable results, and traceable timing within ophthalmic care pathways. We evaluated four-marker documentation completeness and recorded reactivity among patients with recorded completed ophthalmic procedures at a specialist referral hospital in Mogadishu, Somalia. Methods We conducted a retrospective cross-sectional study of patients with recorded completed ophthalmic procedures at Al Ihsan Specialist Hospital from 1 January 2025 to 31 August 2026. The co-primary descriptive outcomes were four-marker documentation completeness and marker-specific recorded reactive proportions for HBsAg, HCV antibody, HIV screening, and an electronic treponemal screening marker recorded under the source-system label “TPHA” within 30 days before or on the index procedure date. One index procedure and one deterministic result per marker were selected per patient. Results The cohort included 10,268 patients with recorded completed ophthalmic procedures; cataract/lens procedures accounted for 7,566 (73.69%). Complete interpretable four-marker results were available for 9,502 patients (92.54%), but documentation varied by pathway: 98.12% in cataract/lens procedures, 94.95% in oculoplasty/adnexal procedures, 40.99% in vitreoretinal procedures, and 27.86% in ocular trauma. Recorded reactivity was 4.18% for HBsAg (401/9,588; 95% CI 3.80–4.60), 0.48% for HCV antibody (46/9,590; 95% CI 0.36–0.64), 0.16% for HIV screening (15/9,589; 95% CI 0.09–0.26), and 11.04% for the electronic treponemal screening marker recorded under the source-system label “TPHA” (1,049/9,506; 95% CI 10.42–11.68); patient-level assay identity and confirmatory status were unavailable. Conclusions Among patients with recorded completed ophthalmic procedures, four-marker documentation was near-complete in the dominant cataract/lens pathway but varied substantially across other pathways, particularly ocular trauma, vitreoretinal procedures, and intravitreal injections. Lower electronic documentation does not establish omitted testing or inadequate care. The findings reflect one hospital’s record workflow and should not be generalized to all patients evaluated for ophthalmic intervention or to other settings.

Authors

Publication Details

Journal
Research Square
Published
2026-11-16
DOI
https://doi.org/10.21203/rs.3.rs-11292598/v1
Primary Topic
Clinical Laboratory Practices and Quality Control
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Preoperative infection-related laboratory documentation and recorded marker reactivity in ophthalmic procedures at a Somali referral hospital: a retrospective cross-sectional study

Liban Hassan Mohamud, Mohamoud Ahmed Mohamed (Dr Shiine), Abdullaahi Abdiasiis Faarah, Abdinasir Aw Dahir
Research Square
Clinical Laboratory Practices and Quality Control
preprint

Preoperative infection-related laboratory documentation and recorded marker reactivity in ophthalmic procedures at a Somali referral hospital: a retrospective cross-sectional study

Liban Hassan Mohamud, Mohamoud Ahmed Mohamed (Dr Shiine), Abdullaahi Abdiasiis Faarah, Abdinasir Aw Dahir
preprint en

Abstract

Abstract Background Reliable preoperative laboratory records require clear test identification, interpretable results, and traceable timing within ophthalmic care pathways. We evaluated four-marker documentation completeness and recorded reactivity among patients with recorded completed ophthalmic procedures at a specialist referral hospital in Mogadishu, Somalia. Methods We conducted a retrospective cross-sectional study of patients with recorded completed ophthalmic procedures at Al Ihsan Specialist Hospital from 1 January 2025 to 31 August 2026. The co-primary descriptive outcomes were four-marker documentation completeness and marker-specific recorded reactive proportions for HBsAg, HCV antibody, HIV screening, and an electronic treponemal screening marker recorded under the source-system label “TPHA” within 30 days before or on the index procedure date. One index procedure and one deterministic result per marker were selected per patient. Results The cohort included 10,268 patients with recorded completed ophthalmic procedures; cataract/lens procedures accounted for 7,566 (73.69%). Complete interpretable four-marker results were available for 9,502 patients (92.54%), but documentation varied by pathway: 98.12% in cataract/lens procedures, 94.95% in oculoplasty/adnexal procedures, 40.99% in vitreoretinal procedures, and 27.86% in ocular trauma. Recorded reactivity was 4.18% for HBsAg (401/9,588; 95% CI 3.80–4.60), 0.48% for HCV antibody (46/9,590; 95% CI 0.36–0.64), 0.16% for HIV screening (15/9,589; 95% CI 0.09–0.26), and 11.04% for the electronic treponemal screening marker recorded under the source-system label “TPHA” (1,049/9,506; 95% CI 10.42–11.68); patient-level assay identity and confirmatory status were unavailable. Conclusions Among patients with recorded completed ophthalmic procedures, four-marker documentation was near-complete in the dominant cataract/lens pathway but varied substantially across other pathways, particularly ocular trauma, vitreoretinal procedures, and intravitreal injections. Lower electronic documentation does not establish omitted testing or inadequate care. The findings reflect one hospital’s record workflow and should not be generalized to all patients evaluated for ophthalmic intervention or to other settings.

Research Square
Good health and well-being
Clinical Laboratory Practices and Quality Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon