Perioperative outcomes after aortic valve replacement via right anterior mini-thoracotomy with a rapid-deployment valve: a consecutive single-centre series

Background/objectives Evidence for aortic valve replacement through right anterior thoracotomy (RAT) using the Edwards Intuity Elite rapid-deployment bioprosthesis remains limited, with only three dedicated single-centre series published to date. We aimed to describe perioperative safety, early haemodynamic performance, permanent pacemaker implantation for third-degree atrioventricular block, and new-onset postoperative atrial fibrillation in a consecutive single-centre cohort. Analyses of factors associated with these two rhythm endpoints were exploratory in nature. Methods This is a retrospective, single-arm, single-centre observational series with no sternotomy, ministernotomy or sutured-valve comparator. We analysed 70 consecutive patients undergoing isolated aortic valve replacement via RAT with the Edwards Intuity Elite bioprosthesis at a single institution. Percutaneous femoral arterial and venous cannulation was used in all cases. Outcomes were described for the whole cohort. For exploratory event-versus-no-event comparisons, Mann–Whitney U and Fisher's exact tests were applied to permanent pacemaker implantation and new-onset atrial fibrillation; Spearman rank correlation and Mann–Whitney U tests explored associations with operative times and discharge pressure gradients. Because only 6 pacemaker and 7 atrial fibrillation events occurred, statistical power was limited. Results Median age was 71.0 years and median EuroSCORE II was 1.0%. Median cross-clamp time was 61.0 min (IQR 54–75) and median cardiopulmonary bypass time was 103.5 min (IQR 84–115). In-hospital mortality was 1.4% (one death from femoral cannulation-site haemorrhage; 95% CI 0.0%–7.7%), and no strokes occurred. Permanent pacemaker implantation was required in 6 patients (8.6%; 95% CI 3.2–17.7%) and new-onset atrial fibrillation occurred in 7 (10.0%; 95% CI 4.1–19.5%); age was significantly associated with pacemaker implantation (median 75.5 vs. 71.0 years, p = 0.038), while other exploratory comparisons were not significant. No moderate or severe paravalvular leak was observed. Median postoperative mean gradient was 8.0 mmHg (IQR 6–10) and median length of stay was 6.0 days (IQR 6.0–7.0). Packed red blood cell transfusion was required in 63 patients (91.3% of 69 evaluable; 95% CI 82.0–96.7%), and reoperation for bleeding in 3 (4.3%; 95% CI 0.9–12.0%). Exploratory analyses detected no statistically significant association with atrial fibrillation or operative times. Implanted valve size correlated weakly and inversely with postoperative mean gradient (Spearman rho = −0.26, p = 0.032). Conclusions In this descriptive, low-risk, single-centre cohort, RAT with a rapid-deployment bioprosthesis was feasible and was followed by low discharge gradients. The observed pacemaker, atrial fibrillation, transfusion, bleeding and access-site event rates are real-world descriptive estimates and do not constitute comparative evidence of benefit over other approaches or prostheses. The small number of events precludes conclusions about predictors. Larger prospective multicentre studies with comparator groups and systematic echocardiographic follow-up are required.

Authors

Institutions

Publication Details

Journal
Frontiers in Cardiovascular Medicine
Published
2026-11-16
DOI
https://doi.org/10.3389/fcvm.2026.1970611
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Perioperative outcomes after aortic valve replacement via right anterior mini-thoracotomy with a rapid-deployment valve: a consecutive single-centre series

Marian Burysz, Adam Ryszard Kowalówka, Sebastian Batkiewicz, Krzysztof Jarmoszewicz et al.
2 links
Frontiers in Cardiovascular Medicine
Cardiac Valve Diseases and Treatments
article

Perioperative outcomes after aortic valve replacement via right anterior mini-thoracotomy with a rapid-deployment valve: a consecutive single-centre series

Marian Burysz, Adam Ryszard Kowalówka, Sebastian Batkiewicz, Krzysztof Jarmoszewicz, Łukasz Jaworski, Michał Kuteń
article en

Abstract

Background/objectives Evidence for aortic valve replacement through right anterior thoracotomy (RAT) using the Edwards Intuity Elite rapid-deployment bioprosthesis remains limited, with only three dedicated single-centre series published to date. We aimed to describe perioperative safety, early haemodynamic performance, permanent pacemaker implantation for third-degree atrioventricular block, and new-onset postoperative atrial fibrillation in a consecutive single-centre cohort. Analyses of factors associated with these two rhythm endpoints were exploratory in nature. Methods This is a retrospective, single-arm, single-centre observational series with no sternotomy, ministernotomy or sutured-valve comparator. We analysed 70 consecutive patients undergoing isolated aortic valve replacement via RAT with the Edwards Intuity Elite bioprosthesis at a single institution. Percutaneous femoral arterial and venous cannulation was used in all cases. Outcomes were described for the whole cohort. For exploratory event-versus-no-event comparisons, Mann–Whitney U and Fisher's exact tests were applied to permanent pacemaker implantation and new-onset atrial fibrillation; Spearman rank correlation and Mann–Whitney U tests explored associations with operative times and discharge pressure gradients. Because only 6 pacemaker and 7 atrial fibrillation events occurred, statistical power was limited. Results Median age was 71.0 years and median EuroSCORE II was 1.0%. Median cross-clamp time was 61.0 min (IQR 54–75) and median cardiopulmonary bypass time was 103.5 min (IQR 84–115). In-hospital mortality was 1.4% (one death from femoral cannulation-site haemorrhage; 95% CI 0.0%–7.7%), and no strokes occurred. Permanent pacemaker implantation was required in 6 patients (8.6%; 95% CI 3.2–17.7%) and new-onset atrial fibrillation occurred in 7 (10.0%; 95% CI 4.1–19.5%); age was significantly associated with pacemaker implantation (median 75.5 vs. 71.0 years, p = 0.038), while other exploratory comparisons were not significant. No moderate or severe paravalvular leak was observed. Median postoperative mean gradient was 8.0 mmHg (IQR 6–10) and median length of stay was 6.0 days (IQR 6.0–7.0). Packed red blood cell transfusion was required in 63 patients (91.3% of 69 evaluable; 95% CI 82.0–96.7%), and reoperation for bleeding in 3 (4.3%; 95% CI 0.9–12.0%). Exploratory analyses detected no statistically significant association with atrial fibrillation or operative times. Implanted valve size correlated weakly and inversely with postoperative mean gradient (Spearman rho = −0.26, p = 0.032). Conclusions In this descriptive, low-risk, single-centre cohort, RAT with a rapid-deployment bioprosthesis was feasible and was followed by low discharge gradients. The observed pacemaker, atrial fibrillation, transfusion, bleeding and access-site event rates are real-world descriptive estimates and do not constitute comparative evidence of benefit over other approaches or prostheses. The small number of events precludes conclusions about predictors. Larger prospective multicentre studies with comparator groups and systematic echocardiographic follow-up are required.

Frontiers in Cardiovascular MedicineVol. 13
Medical University of Silesia (PL), Silesian Center for Heart Disease (PL), Szpital Specjalistyczny im. F. Ceynowy (PL)
Good health and well-being
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon