Hotspot Heat Flow: Conductive Anomaly, Plume Heat Transport and Lithospheric Reheating Budget at Hawaii

If a plume delivers hundreds of gigawatts of excess heat beneath a plate, the seafloor above it should leak measurably more heat than cooling alone predicts, and the size of that leak is one of the oldest quantitative tests of the plume idea at Hawaii. The budget multiplies the adopted heat-flow anomaly by swell area for the total conductive excess, expresses plume heat transport per unit swell area for comparison, computes the diffusion depth heat can reach during the plate's transit across the swell, and prices the reheating of that layer so supply and demand can be set side by side. Headline values are heat anomaly mw per m2 heat = 12; heat swell area km2 heat = 1.327e+06; heat conductive excess gigawatts heat = 15.93; heat plume transport gigawatts heat = 348; heat conductive fraction percent heat = 4.577; heat plume flux density mw per m2 heat = 262.2. The advected remainder is printed explicitly rather than left implicit, since it is the share that decides whether a small surface anomaly counts against the plume or for it.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-16
DOI
https://doi.org/10.5281/zenodo.24274087
Primary Topic
Geological and Geophysical Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Hotspot Heat Flow: Conductive Anomaly, Plume Heat Transport and Lithospheric Reheating Budget at Hawaii

William Alexander Aldred
3 links
Zenodo (CERN European Organization for Nuclear Research)
Geological and Geophysical Studies
article

Hotspot Heat Flow: Conductive Anomaly, Plume Heat Transport and Lithospheric Reheating Budget at Hawaii

William Alexander Aldred
article en

Abstract

If a plume delivers hundreds of gigawatts of excess heat beneath a plate, the seafloor above it should leak measurably more heat than cooling alone predicts, and the size of that leak is one of the oldest quantitative tests of the plume idea at Hawaii. The budget multiplies the adopted heat-flow anomaly by swell area for the total conductive excess, expresses plume heat transport per unit swell area for comparison, computes the diffusion depth heat can reach during the plate's transit across the swell, and prices the reheating of that layer so supply and demand can be set side by side. Headline values are heat anomaly mw per m2 heat = 12; heat swell area km2 heat = 1.327e+06; heat conductive excess gigawatts heat = 15.93; heat plume transport gigawatts heat = 348; heat conductive fraction percent heat = 4.577; heat plume flux density mw per m2 heat = 262.2. The advected remainder is printed explicitly rather than left implicit, since it is the share that decides whether a small surface anomaly counts against the plume or for it.

Zenodo (CERN European Organization for Nuclear Research)
Geological and Geophysical Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon