System-Level Analysis of a DCMD and PEMWE Integrated System for Hydrogen and Water Cogeneration

The integration of desalination and hydrogen production offers a promising pathway to simultaneously address water scarcity and clean energy demands. This study evaluated the feasibility and performance of coupled direct contact membrane distillation (DCMD) and proton exchange membrane water electrolyzer (PEMWE) systems for water–hydrogen cogeneration. A validated steady-state model was developed, incorporating coupled heat and mass transfer in DCMD and electrochemical, thermal, and hydrogen production models for PEMWE. A parametric analysis was conducted under two operational scenarios: (i) full coupling with zero net water output, and (ii) cogeneration of freshwater and hydrogen. The results indicate that system operation is constrained by the balance between DCMD production and PEMWE consumption, yielding a maximum current density of 2.29 A/cm² for a 50 cm² (1–2 kW) electrolyzer supported by a 200 cm² DCMD membrane. The net water production decreased from approximately 0.70 kg/h at zero current density to zero at this limit. The system efficiency decreased with increasing current density owing to rising activation and ohmic losses, as well as higher cooling requirements. By contrast, increasing stack temperature from 50 to 80 °C reduced cell voltage and improved overall efficiency, while lowering cooling demand. The feed temperature strongly enhanced the DCMD productivity, enabling higher feasible operating current densities. In the cogeneration mode, increasing the membrane area to 0.5 m² enabled simultaneous operation, with more than 95% of the produced water remaining available as useful output. These findings provide design insights for the development of water-efficient green hydrogen systems, particularly for deployment in water-limited regions

Authors

Institutions

Publication Details

Published
2026-11-16
DOI
https://doi.org/10.64589/juri/231609
Primary Topic
Hybrid Renewable Energy Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

System-Level Analysis of a DCMD and PEMWE Integrated System for Hydrogen and Water Cogeneration

Atia E. Khalifa, Alaa Mohammed Ahmed
7 links
Hybrid Renewable Energy Systems
article

System-Level Analysis of a DCMD and PEMWE Integrated System for Hydrogen and Water Cogeneration

Atia E. Khalifa, Alaa Mohammed Ahmed
article en

Abstract

The integration of desalination and hydrogen production offers a promising pathway to simultaneously address water scarcity and clean energy demands. This study evaluated the feasibility and performance of coupled direct contact membrane distillation (DCMD) and proton exchange membrane water electrolyzer (PEMWE) systems for water–hydrogen cogeneration. A validated steady-state model was developed, incorporating coupled heat and mass transfer in DCMD and electrochemical, thermal, and hydrogen production models for PEMWE. A parametric analysis was conducted under two operational scenarios: (i) full coupling with zero net water output, and (ii) cogeneration of freshwater and hydrogen. The results indicate that system operation is constrained by the balance between DCMD production and PEMWE consumption, yielding a maximum current density of 2.29 A/cm² for a 50 cm² (1–2 kW) electrolyzer supported by a 200 cm² DCMD membrane. The net water production decreased from approximately 0.70 kg/h at zero current density to zero at this limit. The system efficiency decreased with increasing current density owing to rising activation and ohmic losses, as well as higher cooling requirements. By contrast, increasing stack temperature from 50 to 80 °C reduced cell voltage and improved overall efficiency, while lowering cooling demand. The feed temperature strongly enhanced the DCMD productivity, enabling higher feasible operating current densities. In the cogeneration mode, increasing the membrane area to 0.5 m² enabled simultaneous operation, with more than 95% of the produced water remaining available as useful output. These findings provide design insights for the development of water-efficient green hydrogen systems, particularly for deployment in water-limited regions

Vol. 2(3B)
King Fahd University of Petroleum and Minerals (SA)
King Fahd University of Petroleum and Minerals
Affordable and clean energy, Clean water and sanitation, Climate action
Hybrid Renewable Energy Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon