Design Blueprint: A Seawater Air-Conditioning District-Cooling System with an Energy-Recovery Cycle, Sized by Pumping and Cooling Budgets

Design blueprint derived from the source paper (DOI 10.5281/zenodo.24291664): Deep cold water is pumped ashore, passed through a small closed-cycle unit that recovers part of the pumping energy as electricity, then circulated through district heat exchangers that cool buildings directly before the warmed water returns to the sea. Its operating principle: seawater air-conditioning district cooling, where the deep ocean replaces the refrigeration plant: cold water itself is the refrigerant, delivered by pipe to building heat exchangers. Headline values are swa surface temperature swa c = 27; swa deep temperature swa c = 5; swa temperature difference swa k = 22; swa carnot efficiency swa percent = 7.33; swa adopted cycle swa efficiency percent = 3.665; swa warm flow swa m3 per s swa = 4. A conventional chiller spends a unit of electricity to move five units of heat; this system spends pumps instead, and the deep ocean supplies the cold for free. SIMULATED, NOT MEASURED. Hotel guests, office workers and hospital patients feel this system only as cool air. District cooling is a municipal comfort service; the design's pipes and pumps serve buildings, never any harmful purpose. Status: DESIGN BLUEPRINT — SIMULATED, NOT MEASURED — NOT BUILT. All numbers are simulated values from the source paper's computation, deposited with this blueprint as compute.py and results.json. The design is a civilian science system for Titan aerial exploration and sampling, and has no targeting or weapon application. AI-use disclosure: Dave, an AI research system, assisted with the computation and drafting under the author's direction; author of record William Alexander Aldred.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-16
DOI
https://doi.org/10.5281/zenodo.24292224
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Design Blueprint: A Seawater Air-Conditioning District-Cooling System with an Energy-Recovery Cycle, Sized by Pumping and Cooling Budgets

William Alexander Aldred
8 links
Zenodo (CERN European Organization for Nuclear Research)
Refrigeration and Air Conditioning Technologies
article

Design Blueprint: A Seawater Air-Conditioning District-Cooling System with an Energy-Recovery Cycle, Sized by Pumping and Cooling Budgets

William Alexander Aldred
article en

Abstract

Design blueprint derived from the source paper (DOI 10.5281/zenodo.24291664): Deep cold water is pumped ashore, passed through a small closed-cycle unit that recovers part of the pumping energy as electricity, then circulated through district heat exchangers that cool buildings directly before the warmed water returns to the sea. Its operating principle: seawater air-conditioning district cooling, where the deep ocean replaces the refrigeration plant: cold water itself is the refrigerant, delivered by pipe to building heat exchangers. Headline values are swa surface temperature swa c = 27; swa deep temperature swa c = 5; swa temperature difference swa k = 22; swa carnot efficiency swa percent = 7.33; swa adopted cycle swa efficiency percent = 3.665; swa warm flow swa m3 per s swa = 4. A conventional chiller spends a unit of electricity to move five units of heat; this system spends pumps instead, and the deep ocean supplies the cold for free. SIMULATED, NOT MEASURED. Hotel guests, office workers and hospital patients feel this system only as cool air. District cooling is a municipal comfort service; the design's pipes and pumps serve buildings, never any harmful purpose. Status: DESIGN BLUEPRINT — SIMULATED, NOT MEASURED — NOT BUILT. All numbers are simulated values from the source paper's computation, deposited with this blueprint as compute.py and results.json. The design is a civilian science system for Titan aerial exploration and sampling, and has no targeting or weapon application. AI-use disclosure: Dave, an AI research system, assisted with the computation and drafting under the author's direction; author of record William Alexander Aldred.

Zenodo (CERN European Organization for Nuclear Research)
Affordable and clean energy, Climate action, Industry, innovation and infrastructure
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon