Numerical Study of Flow and Particle Deposition in Damaged Wall-Flow Filter Channels with an Internal Crack

Severe thermal regeneration can create internal cracks in wall-flow particulate filters, which allow particles to bypass the porous walls. This study presents a numerical investigation of the time-dependent three-dimensional gas–particle flow in filter channels with an internal crack near the entrance, at an intermediate position, or near the exit. The channel Reynolds numbers examined range from 204 to 1632. The flow is governed by the Navier–Stokes equations in the clear-fluid regions and a Brinkman–Forchheimer formulation in the porous walls and plugs. Trajectories of nanoparticles with a diameter of 200 nm are calculated using Lagrangian tracking with slip-corrected drag and Brownian forces, and deposition is determined from particle–wall intersections. The results show that the crack provides a direct passage between neighboring inlet and outlet channels, producing an intense three-dimensional cross-flow with local separation and recirculation. The fraction of inlet flow passing through the opening reduces as the Reynolds number increases, and it increases as the crack moves toward the exit. The associated changes in the through-wall flow determine the spatial distribution of deposited particles, with enhanced deposition downstream of the crack and attenuated deposition upstream of it at higher values of the Reynolds number. For all crack positions, the filtration efficiency is increased with an increasing Reynolds number, but it is decreased as the crack moves towards the exit. Over the conditions examined, the efficiency rises from approximately 45–53% at a Reynolds number of 204 to 74–89% at 1632, depending on the crack position.

Authors

Institutions

Publication Details

Journal
Purification
Published
2026-11-16
DOI
https://doi.org/10.3390/purification2040019
Primary Topic
Aerosol Filtration and Electrostatic Precipitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Numerical Study of Flow and Particle Deposition in Damaged Wall-Flow Filter Channels with an Internal Crack

Fotini Tzorbatzoglou, Chris D. Dritselis
2 links
Purification
Aerosol Filtration and Electrostatic Precipitation
article

Numerical Study of Flow and Particle Deposition in Damaged Wall-Flow Filter Channels with an Internal Crack

Fotini Tzorbatzoglou, Chris D. Dritselis
article en

Abstract

Severe thermal regeneration can create internal cracks in wall-flow particulate filters, which allow particles to bypass the porous walls. This study presents a numerical investigation of the time-dependent three-dimensional gas–particle flow in filter channels with an internal crack near the entrance, at an intermediate position, or near the exit. The channel Reynolds numbers examined range from 204 to 1632. The flow is governed by the Navier–Stokes equations in the clear-fluid regions and a Brinkman–Forchheimer formulation in the porous walls and plugs. Trajectories of nanoparticles with a diameter of 200 nm are calculated using Lagrangian tracking with slip-corrected drag and Brownian forces, and deposition is determined from particle–wall intersections. The results show that the crack provides a direct passage between neighboring inlet and outlet channels, producing an intense three-dimensional cross-flow with local separation and recirculation. The fraction of inlet flow passing through the opening reduces as the Reynolds number increases, and it increases as the crack moves toward the exit. The associated changes in the through-wall flow determine the spatial distribution of deposited particles, with enhanced deposition downstream of the crack and attenuated deposition upstream of it at higher values of the Reynolds number. For all crack positions, the filtration efficiency is increased with an increasing Reynolds number, but it is decreased as the crack moves towards the exit. Over the conditions examined, the efficiency rises from approximately 45–53% at a Reynolds number of 204 to 74–89% at 1632, depending on the crack position.

PurificationVol. 2(4)
University of Thessaly (GR)
Aerosol Filtration and Electrostatic Precipitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon