Psychometric Function Selection and Reference Values for a Computerized Gap-in-Noise Paradigm in Normal-Hearing Young Adults

Background: Gap detection in continuous noise is a widely used operational measure of auditory temporal resolution, but the estimated threshold depends on how the psychometric relationship between gap duration and detection probability is modeled. Because published gap-detection thresholds are procedure- and implementation-specific, reference data should be established whenever a new implementation is introduced. The present study reports reference thresholds and evaluates candidate psychometric functions for a computerized gap-in-noise (GIN) paradigm. Methods: Sixty normal-hearing young adults (30 female, 30 male; age 18-24 years) were tested binaurally with a computerized GIN procedure using a 3-down, 1-up adaptive staircase across a 2-20 ms gap-duration grid, with verbal gap counting as the response. For each of the 120 ears, Weibull, Florentine logistic, and 2-parameter logistic psychometric functions were fit, goodness-of-fit was quantified with the Hosmer–Lemeshow statistic, and thresholds were extracted at the 50% and 75% detection criteria. Results: Weibull 75% gap-detection threshold (GDT75) averaged 3.18 ms (standard deviation [SD] 0.20, range 2.22-3.70). Interaural agreement was high (mean right-minus-left difference −0.04 ms; Bland–Altman 95% limits of agreement −0.62 to +0.54 ms), and no participant-level gender difference was detected at either criterion. The Weibull function returned acceptable Hosmer–Lemeshow fits and finite thresholds for 100% of ears, whereas the 2-parameter logistic returned non-finite thresholds for all 120 ears despite acceptable goodness-of-fit. Conclusion: These findings provide procedure-specific reference values and support the Weibull function as the primary psychometric model for this paradigm. Cite this article as: Çögen T, Kara E. Psychometric function selection and reference values for a computerized gap-in-noise paradigm in normal-hearing young adults. Balkan ORL-HNS. 2026, 3, 0156. doi: 10.5152/bohns.2026.26156.

Authors

Institutions

Publication Details

Journal
Balkan ORL-HNS.
Published
2026-11-16
DOI
https://doi.org/10.5152/bohns.2026.26156
Primary Topic
Hearing Loss and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Psychometric Function Selection and Reference Values for a Computerized Gap-in-Noise Paradigm in Normal-Hearing Young Adults

Eyyüp Kara, Talha Çögen
Balkan ORL-HNS.
Hearing Loss and Rehabilitation
article

Psychometric Function Selection and Reference Values for a Computerized Gap-in-Noise Paradigm in Normal-Hearing Young Adults

Eyyüp Kara, Talha Çögen
article en

Abstract

Background: Gap detection in continuous noise is a widely used operational measure of auditory temporal resolution, but the estimated threshold depends on how the psychometric relationship between gap duration and detection probability is modeled. Because published gap-detection thresholds are procedure- and implementation-specific, reference data should be established whenever a new implementation is introduced. The present study reports reference thresholds and evaluates candidate psychometric functions for a computerized gap-in-noise (GIN) paradigm. Methods: Sixty normal-hearing young adults (30 female, 30 male; age 18-24 years) were tested binaurally with a computerized GIN procedure using a 3-down, 1-up adaptive staircase across a 2-20 ms gap-duration grid, with verbal gap counting as the response. For each of the 120 ears, Weibull, Florentine logistic, and 2-parameter logistic psychometric functions were fit, goodness-of-fit was quantified with the Hosmer–Lemeshow statistic, and thresholds were extracted at the 50% and 75% detection criteria. Results: Weibull 75% gap-detection threshold (GDT75) averaged 3.18 ms (standard deviation [SD] 0.20, range 2.22-3.70). Interaural agreement was high (mean right-minus-left difference −0.04 ms; Bland–Altman 95% limits of agreement −0.62 to +0.54 ms), and no participant-level gender difference was detected at either criterion. The Weibull function returned acceptable Hosmer–Lemeshow fits and finite thresholds for 100% of ears, whereas the 2-parameter logistic returned non-finite thresholds for all 120 ears despite acceptable goodness-of-fit. Conclusion: These findings provide procedure-specific reference values and support the Weibull function as the primary psychometric model for this paradigm. Cite this article as: Çögen T, Kara E. Psychometric function selection and reference values for a computerized gap-in-noise paradigm in normal-hearing young adults. Balkan ORL-HNS. 2026, 3, 0156. doi: 10.5152/bohns.2026.26156.

Balkan ORL-HNS.Vol. 3(1)
Bingöl University (TR), Istanbul University-Cerrahpaşa (TR), Istanbul University (TR)
Türkiye Bilimsel ve Teknolojik Araştırma Kurumu
Good health and well-being
Hearing Loss and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon