Hydrophilic–hydrophobic flow-field engineering for passive water management in high-power-density PEMFCs

Effective water management remains a major limitation to high-power-density proton exchange membrane fuel cells (PEMFCs), where excessive liquid-water accumulation restricts oxygen transport and intensifies concentration losses. This study investigates a spatially engineered hydrophilic–hydrophobic flow-field strategy for passive water management, with particular emphasis on the orientation of surface wettability relative to reactant flow. Four configurations are evaluated using a three-dimensional, non-isothermal, two-phase electrochemical model: uniform wettability, hydrophilic-to-hydrophobic (Phil → Phob), hydrophobic-to-hydrophilic (Phob → Phil), and alternating wettability. The Phob → Phil configuration exhibits the best overall performance, increasing peak power density from 1.78 to 2.21 W cm -2 , corresponding to a 24.2% improvement over the reference case. Under high-load conditions, it reduces flooded cathode area from 31% to 15%, oxygen depletion from 34% to 18%, and mass-transport losses from 205 to 108 mV. Temperature non-uniformity and total exergy destruction are further reduced by approximately 42.9% and 28.4%, respectively. Moreover, 89.8% of the active area operates within ±10% of the mean current density, demonstrating substantially improved electrochemical uniformity. Capillary-pressure analysis reveals that performance is governed not simply by wettability contrast, but critically by its spatial direction along the flow path. These findings establish directional hydrophilic–hydrophobic engineering as an effective passive approach for coordinating water removal, oxygen accessibility, and membrane hydration while extending stable high-power-density PEMFC operation.

Authors

Institutions

Publication Details

Journal
Frontiers in Chemistry
Published
2026-11-16
DOI
https://doi.org/10.3389/fchem.2026.1990733
Primary Topic
Fuel Cells and Related Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Hydrophilic–hydrophobic flow-field engineering for passive water management in high-power-density PEMFCs

Akram E. Zeid, Mohammad R. Almajali, Nathan Kawansson, Ahmed M. Salem et al.
3 links
Frontiers in Chemistry
Fuel Cells and Related Materials
article

Hydrophilic–hydrophobic flow-field engineering for passive water management in high-power-density PEMFCs

Akram E. Zeid, Mohammad R. Almajali, Nathan Kawansson, Ahmed M. Salem, Saad S. Alrwashdeh
article en

Abstract

Effective water management remains a major limitation to high-power-density proton exchange membrane fuel cells (PEMFCs), where excessive liquid-water accumulation restricts oxygen transport and intensifies concentration losses. This study investigates a spatially engineered hydrophilic–hydrophobic flow-field strategy for passive water management, with particular emphasis on the orientation of surface wettability relative to reactant flow. Four configurations are evaluated using a three-dimensional, non-isothermal, two-phase electrochemical model: uniform wettability, hydrophilic-to-hydrophobic (Phil → Phob), hydrophobic-to-hydrophilic (Phob → Phil), and alternating wettability. The Phob → Phil configuration exhibits the best overall performance, increasing peak power density from 1.78 to 2.21 W cm -2 , corresponding to a 24.2% improvement over the reference case. Under high-load conditions, it reduces flooded cathode area from 31% to 15%, oxygen depletion from 34% to 18%, and mass-transport losses from 205 to 108 mV. Temperature non-uniformity and total exergy destruction are further reduced by approximately 42.9% and 28.4%, respectively. Moreover, 89.8% of the active area operates within ±10% of the mean current density, demonstrating substantially improved electrochemical uniformity. Capillary-pressure analysis reveals that performance is governed not simply by wettability contrast, but critically by its spatial direction along the flow path. These findings establish directional hydrophilic–hydrophobic engineering as an effective passive approach for coordinating water removal, oxygen accessibility, and membrane hydration while extending stable high-power-density PEMFC operation.

Frontiers in ChemistryVol. 14
Mutah University (JO), Sharjah Maritime Academy (AE), Rabdan Academy (AE)
Affordable and clean energy, Clean water and sanitation
Fuel Cells and Related Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon