Fuel cell based tri-generation system for greenhouses- part 2. Cooling
Cooling for semi-sealed greenhouses has emerged as a critical challenge, since restricted natural ventilation directly exposes crops to severe summer heat stress, threatening productivity and stability. This study extends the winter-focused Part I to summer operation by conducting a cooling-mode analysis of a hybrid trigeneration system, with the greenhouse heat-load model and major component models calibrated and validated against experimental data collected at the demonstration site, the cooling-load model reproducing the measured energy to within 2.22%. Two operational strategies were compared: an adaptive mode prioritizing waste-heat and solar-driven adsorption cooling, and a scheduled mode with predictive scheduling and chilled-water storage. The system met cooling loads of 25–75 kW on typical hot days and 94 kW on extreme hot days, while maintaining indoor air below 32 °C. Scheduled control reduced operational energy cost to 0.060–0.067 $/kWh, compared with 0.061–0.069 $/kWh for the adaptive mode. Under medium reference conditions, benchmark-based comparison showed positive primary energy savings of 5.9–19.9% and carbon saving ratios of 13.5–47.5% in cooling mode, although the magnitude of the benefit was sensitive to summer operating conditions. Local sensitivity analysis showed that a 10% reduction in fuel cell efficiency increased operational energy cost by 12.7%, while the same reduction in coefficient of performance of electrical heat pump increased them by 9.3%. These results correspond to the direct heat-utilization boundary; a complementary bounding analysis that accounts for the electricity of the temperature-upgrade step, together with a break-even criterion for the thermally driven cooling chain, is provided in the Discussion. This study provides one of the first techno-economic and benchmark-based assessments of greenhouse trigeneration cooling, demonstrating its potential to stabilize the summer greenhouse climate and support harvest extension, and clarifying, on a scenario basis, the year-round role of the proposed platform for controlled horticulture.
Authors
- Byeonghyun Kang (ORCID: https://orcid.org/0009-0002-4725-895X)
- Tuananh Bui (ORCID: https://orcid.org/0009-0005-7045-4133)
- Soyeon Kim (ORCID: https://orcid.org/0000-0001-5055-5678)
- Yonggyun Bae (ORCID: https://orcid.org/0000-0002-4394-3194)
- Young Sang Kim (ORCID: https://orcid.org/0000-0001-5057-4131)
- Dong Keun Lee
- Jin Young Park
Institutions
- Dongguk University (KR)
- Korea Institute of Machinery & Materials (KR)
- Chung-Ang University (KR)
- Korea University of Science and Technology (KR)
Publication Details
- Journal
- Energy Reports
- Published
- 2026-11-17
- DOI
- https://doi.org/10.1016/j.egyr.2026.109912
- Primary Topic
- Greenhouse Technology and Climate Control
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Korea Institute of Machinery and Materials
- National Research Foundation of Korea
- Ministry of Science and ICT, South Korea