Evaluation of the Compaction Simulator to Industrial Tablet Press Transferability for a Fixed-Dose Combination Immediate-Release Formulation

Compaction simulators are widely used to reduce material consumption during process development, but the conditions under which simulator-derived data reliably predict industrial rotary press performance remain incompletely understood for multi-component, viscoelastic formulations. This study evaluated agreement between a Styl’One Nano compaction simulator and a 32-station industrial rotary press (PharmaLand PTP-32) for a fixed-dose combination of ibuprofen, paracetamol, and caffeine, using a matched Box–Behnken design executed in parallel on both instruments via equivalent dwell times. Agreement across four critical quality attributes (tensile strength, mass variability, friability, and disintegration time) was assessed via design of experiments (DoE) coefficient analysis and Bland–Altman comparison. Punch displacement profiling revealed peak velocity ratios of 2.4–3.9 (simulator/press) despite matched dwell times, and strain rate sensitivity testing confirmed that this kinematic mismatch underlies the observed divergence. Because the two instruments used punches of different compression area, a response surface analysis was performed on a common compaction-pressure basis. The divergence in tensile strength and friability persisted after removal of this geometric confound, confirming that it reflects genuine differences in compaction behavior. Convergence followed a trade-off boundary rather than a simple threshold: the pre-compression pressure required for statistical equivalence fell from 21.3 to 9.4 MPa as main compression pressure rose from 130 to 182 MPa, while at 120 MPa no pre-compression level achieved agreement. These findings show that simulator-to-press transferability is CQA- and process-window-specific.

Authors

Institutions

Publication Details

Journal
Scientia Pharmaceutica
Published
2026-11-16
DOI
https://doi.org/10.3390/scipharm94040114
Primary Topic
Granular flow and fluidized beds
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Evaluation of the Compaction Simulator to Industrial Tablet Press Transferability for a Fixed-Dose Combination Immediate-Release Formulation

Alexandru D. Gavan, Ioan Tomuță, Marcela Achim, Béla Kovács et al.
Scientia Pharmaceutica
Granular flow and fluidized beds
article

Evaluation of the Compaction Simulator to Industrial Tablet Press Transferability for a Fixed-Dose Combination Immediate-Release Formulation

Alexandru D. Gavan, Ioan Tomuță, Marcela Achim, Béla Kovács, Sonia Iurian, Alina Silvia Porfire, Tibor Casian, Razvan Chereches, Alexandru Oprea, Elena-Camelia Norocel
article en

Abstract

Compaction simulators are widely used to reduce material consumption during process development, but the conditions under which simulator-derived data reliably predict industrial rotary press performance remain incompletely understood for multi-component, viscoelastic formulations. This study evaluated agreement between a Styl’One Nano compaction simulator and a 32-station industrial rotary press (PharmaLand PTP-32) for a fixed-dose combination of ibuprofen, paracetamol, and caffeine, using a matched Box–Behnken design executed in parallel on both instruments via equivalent dwell times. Agreement across four critical quality attributes (tensile strength, mass variability, friability, and disintegration time) was assessed via design of experiments (DoE) coefficient analysis and Bland–Altman comparison. Punch displacement profiling revealed peak velocity ratios of 2.4–3.9 (simulator/press) despite matched dwell times, and strain rate sensitivity testing confirmed that this kinematic mismatch underlies the observed divergence. Because the two instruments used punches of different compression area, a response surface analysis was performed on a common compaction-pressure basis. The divergence in tensile strength and friability persisted after removal of this geometric confound, confirming that it reflects genuine differences in compaction behavior. Convergence followed a trade-off boundary rather than a simple threshold: the pre-compression pressure required for statistical equivalence fell from 21.3 to 9.4 MPa as main compression pressure rose from 130 to 182 MPa, while at 120 MPa no pre-compression level achieved agreement. These findings show that simulator-to-press transferability is CQA- and process-window-specific.

Scientia PharmaceuticaVol. 94(4)
Iuliu Hațieganu University of Medicine and Pharmacy (RO), Universitatea de Medicină, Farmacie, Științe și Tehnologie „George Emil Palade” din Târgu Mureș (RO), Babeș-Bolyai University (RO)
Granular flow and fluidized beds
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon