Deciphering Temperature–Humidity Coupling in Proton Exchange Membrane Fuel Cells: Multiphysics Insights into Performance, Water Management, and Operating Limits

Climate-driven temperature and humidity extremes can substantially alter the coupled electrochemical, thermal, and transport processes governing proton exchange membrane fuel cell (PEMFC) performance, yet their implications for environmental resilience remain insufficiently quantified. This study develops a three-dimensional, non-isothermal multiphysics framework to assess PEMFC operation across 16 temperature–relative-humidity scenarios spanning 20–80 °C and 20–100% RH. Electrochemical kinetics, species and heat transport, membrane hydration, liquid-water behavior, oxygen availability, and spatial current-density characteristics are evaluated concurrently to identify environmentally induced operating limitations. The results reveal two competing failure regimes: hot–dry exposure promotes membrane dehydration, increased protonic resistance, spatial non-uniformity, and severe power deterioration, whereas excessive humidification progressively increases liquid-water accumulation, oxygen-transport resistance, pressure drop, and auxiliary pumping requirements. A balanced regime emerges around 60 °C and 80% RH (C11), where membrane hydration and oxygen accessibility are simultaneously maintained. Under this condition, oxygen utilization reaches approximately 79.4%, the admissible current density increases to 1.98 A cm−2, and net power density reaches approximately 1.04 W cm−2. In contrast, the hot–dry C13 condition restricts the admissible current density to 0.74 A cm−2 and reduces net power density to approximately 0.49 W cm−2. The findings demonstrate that PEMFC climate resilience is governed by the balance between hydration preservation and reactant/water transport rather than optimization of temperature or humidity independently, providing a physics-based basis for climate-adaptive control and robust hydrogen-power-system design.

Authors

Institutions

Publication Details

Journal
Clean Technologies
Published
2026-11-16
DOI
https://doi.org/10.3390/cleantechnol8060188
Primary Topic
Fuel Cells and Related Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Deciphering Temperature–Humidity Coupling in Proton Exchange Membrane Fuel Cells: Multiphysics Insights into Performance, Water Management, and Operating Limits

Akram E. Zeid, Mohammad R. Almajali, Nathan Kawansson, Ahmed M. Salem et al.
3 links
Clean Technologies
Fuel Cells and Related Materials
article

Deciphering Temperature–Humidity Coupling in Proton Exchange Membrane Fuel Cells: Multiphysics Insights into Performance, Water Management, and Operating Limits

Akram E. Zeid, Mohammad R. Almajali, Nathan Kawansson, Ahmed M. Salem, Saad S. Alrwashdeh
article en

Abstract

Climate-driven temperature and humidity extremes can substantially alter the coupled electrochemical, thermal, and transport processes governing proton exchange membrane fuel cell (PEMFC) performance, yet their implications for environmental resilience remain insufficiently quantified. This study develops a three-dimensional, non-isothermal multiphysics framework to assess PEMFC operation across 16 temperature–relative-humidity scenarios spanning 20–80 °C and 20–100% RH. Electrochemical kinetics, species and heat transport, membrane hydration, liquid-water behavior, oxygen availability, and spatial current-density characteristics are evaluated concurrently to identify environmentally induced operating limitations. The results reveal two competing failure regimes: hot–dry exposure promotes membrane dehydration, increased protonic resistance, spatial non-uniformity, and severe power deterioration, whereas excessive humidification progressively increases liquid-water accumulation, oxygen-transport resistance, pressure drop, and auxiliary pumping requirements. A balanced regime emerges around 60 °C and 80% RH (C11), where membrane hydration and oxygen accessibility are simultaneously maintained. Under this condition, oxygen utilization reaches approximately 79.4%, the admissible current density increases to 1.98 A cm−2, and net power density reaches approximately 1.04 W cm−2. In contrast, the hot–dry C13 condition restricts the admissible current density to 0.74 A cm−2 and reduces net power density to approximately 0.49 W cm−2. The findings demonstrate that PEMFC climate resilience is governed by the balance between hydration preservation and reactant/water transport rather than optimization of temperature or humidity independently, providing a physics-based basis for climate-adaptive control and robust hydrogen-power-system design.

Clean TechnologiesVol. 8(6)
Mutah University (JO), University of Sharjah (AE), Sharjah Maritime Academy (AE), Rabdan Academy (AE)
Affordable and clean energy, Climate action
Fuel Cells and Related Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon