Initial Experience with the 6–10 mm TIPS Endoprosthesis: Technical Feasibility and Early Clinical Outcomes

PURPOSE: To evaluate the technical feasibility, hemodynamic effects, and early clinical outcomes of the 6-10 mm GORE VIATORR TIPS Endoprosthesis with Controlled Expansion, which extends the prior 8 mm deployment floor to 6 mm. MATERIALS AND METHODS: This single-center retrospective study included consecutive patients who underwent de novo transjugular intrahepatic portosystemic shunt (TIPS) creation with the 6-10 mm device between April and July 2026. Technical success was defined as portosystemic pressure gradient (PSPG) below 12 mmHg or ≥ 50% reduction from baseline. RESULT: Twelve patients (8 females, 4 males; mean age 57.1 ± 15.7 years; range 32-83 years) were included. Indications for TIPS creation were variceal hemorrhage (50.0%; n = 6/12), refractory ascites (33.3%; n = 4/12), and refractory hepatic hydrothorax (16.7%; n = 2/12). Final stent diameter was less than 8 mm in 91.7% (n = 11/12) of patients. Technical success was achieved in all patients, with mean PSPG decreasing from 16.7 ± 7.7 to 7.7 ± 2.9 mmHg (P < .001) and no immediate adverse events. Shunt patency was 100% at short imaging follow-up (mean, 35.6 ± 25.0 days), with no reinterventions. No recurrent variceal hemorrhage occurred, and ascites improved or resolved in 77.8% (n = 7/9) of patients at short clinical follow-up (mean, 50.5 ± 23.3 days). Four of 11 patients (36.4%) experienced symptomatic HE after TIPS creation and one patient (9.1%) died during the follow-up period. CONCLUSION: TIPS creation using the 6-10 mm device is a technically feasible strategy with adequate short-term hemodynamic response.

Authors

Institutions

Publication Details

Journal
CardioVascular and Interventional Radiology
Published
2026-11-16
DOI
https://doi.org/10.1007/s00270-026-04690-2
Primary Topic
Liver Disease and Transplantation
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Initial Experience with the 6–10 mm TIPS Endoprosthesis: Technical Feasibility and Early Clinical Outcomes

David S. Shin, Eric D. Cyphers, Jeffrey Forris Beecham Chick, Samantha S Chau et al.
CardioVascular and Interventional Radiology
Liver Disease and Transplantation
article

Initial Experience with the 6–10 mm TIPS Endoprosthesis: Technical Feasibility and Early Clinical Outcomes

David S. Shin, Eric D. Cyphers, Jeffrey Forris Beecham Chick, Samantha S Chau, Ashish R. Vyas, Ryan D. Murray, Matthew Abad-Santos
article en

Abstract

PURPOSE: To evaluate the technical feasibility, hemodynamic effects, and early clinical outcomes of the 6-10 mm GORE VIATORR TIPS Endoprosthesis with Controlled Expansion, which extends the prior 8 mm deployment floor to 6 mm. MATERIALS AND METHODS: This single-center retrospective study included consecutive patients who underwent de novo transjugular intrahepatic portosystemic shunt (TIPS) creation with the 6-10 mm device between April and July 2026. Technical success was defined as portosystemic pressure gradient (PSPG) below 12 mmHg or ≥ 50% reduction from baseline. RESULT: Twelve patients (8 females, 4 males; mean age 57.1 ± 15.7 years; range 32-83 years) were included. Indications for TIPS creation were variceal hemorrhage (50.0%; n = 6/12), refractory ascites (33.3%; n = 4/12), and refractory hepatic hydrothorax (16.7%; n = 2/12). Final stent diameter was less than 8 mm in 91.7% (n = 11/12) of patients. Technical success was achieved in all patients, with mean PSPG decreasing from 16.7 ± 7.7 to 7.7 ± 2.9 mmHg (P < .001) and no immediate adverse events. Shunt patency was 100% at short imaging follow-up (mean, 35.6 ± 25.0 days), with no reinterventions. No recurrent variceal hemorrhage occurred, and ascites improved or resolved in 77.8% (n = 7/9) of patients at short clinical follow-up (mean, 50.5 ± 23.3 days). Four of 11 patients (36.4%) experienced symptomatic HE after TIPS creation and one patient (9.1%) died during the follow-up period. CONCLUSION: TIPS creation using the 6-10 mm device is a technically feasible strategy with adequate short-term hemodynamic response.

CardioVascular and Interventional Radiology
University of Southern California (US)
University of Southern California
Good health and well-being
Liver Disease and Transplantation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon