Polyaluminum chloride/chitosan hybrid coagulation for carmoisine removal from aqueous solutions: Process optimization, combined performance, and mechanistic assessment

The removal of persistent anionic dyes from industrial wastewater remains a significant treatment challenge. This study evaluated a polyaluminum chloride/chitosan (PAC/CS) hybrid coagulation system for Carmoisine (CR) removal from synthetic aqueous solutions. Response surface methodology with a Box–Behnken design was used to examine the effects of initial pH (4–10), PAC dosage (50–300 mg/L), CS dosage (10–100 mg/L), and initial CR concentration (10–50 mg/L). The findings showed that the maximum CR removal efficiency obtained through numerical optimization was 87.47% at a PAC dosage of 175 mg/L, a CS dosage of 10 mg/L, a pH of 4, and an initial CR concentration of 30 mg/L. Independent validation in triplicate achieved 86.38 ± 2.47% removal, with a relative prediction error of 1.25%. CS dosage and pH had the largest linear effects in the coded model, while interactions between initial CR concentration and CS dosage and between CS and PAC dosages were statistically significant. The pseudo-first-order model fitted the kinetic data more consistently than the pseudo-second-order model, and the Temkin model provided the closest fit among the evaluated isotherms. These fits describe the observed behavior without establishing a specific removal mechanism. Characterization revealed a rough, heterogeneous surface and a predominantly amorphous structure. FTIR spectral changes suggested the involvement of amino and hydroxyl groups in dye–coagulant interactions, while a single pre-treatment zeta-potential measurement yielded −5.43 mV under the measurement conditions. PAC/CS achieved effective CR removal within the investigated laboratory conditions. Further evaluation of residual aluminum, sludge characteristics, treatment costs, and performance in real wastewater is required to determine practical applicability and environmental performance.

Authors

Institutions

Publication Details

Journal
Next Materials
Published
2026-11-16
DOI
https://doi.org/10.1016/j.nxmate.2026.104067
Primary Topic
Coagulation and Flocculation Studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Polyaluminum chloride/chitosan hybrid coagulation for carmoisine removal from aqueous solutions: Process optimization, combined performance, and mechanistic assessment

Ziaeddin Bonyadi, Afsaneh Esmaeili Nasrabadi, Masoume Farashiani
2 links
Next Materials
Coagulation and Flocculation Studies
article

Polyaluminum chloride/chitosan hybrid coagulation for carmoisine removal from aqueous solutions: Process optimization, combined performance, and mechanistic assessment

Ziaeddin Bonyadi, Afsaneh Esmaeili Nasrabadi, Masoume Farashiani
article en

Abstract

The removal of persistent anionic dyes from industrial wastewater remains a significant treatment challenge. This study evaluated a polyaluminum chloride/chitosan (PAC/CS) hybrid coagulation system for Carmoisine (CR) removal from synthetic aqueous solutions. Response surface methodology with a Box–Behnken design was used to examine the effects of initial pH (4–10), PAC dosage (50–300 mg/L), CS dosage (10–100 mg/L), and initial CR concentration (10–50 mg/L). The findings showed that the maximum CR removal efficiency obtained through numerical optimization was 87.47% at a PAC dosage of 175 mg/L, a CS dosage of 10 mg/L, a pH of 4, and an initial CR concentration of 30 mg/L. Independent validation in triplicate achieved 86.38 ± 2.47% removal, with a relative prediction error of 1.25%. CS dosage and pH had the largest linear effects in the coded model, while interactions between initial CR concentration and CS dosage and between CS and PAC dosages were statistically significant. The pseudo-first-order model fitted the kinetic data more consistently than the pseudo-second-order model, and the Temkin model provided the closest fit among the evaluated isotherms. These fits describe the observed behavior without establishing a specific removal mechanism. Characterization revealed a rough, heterogeneous surface and a predominantly amorphous structure. FTIR spectral changes suggested the involvement of amino and hydroxyl groups in dye–coagulant interactions, while a single pre-treatment zeta-potential measurement yielded −5.43 mV under the measurement conditions. PAC/CS achieved effective CR removal within the investigated laboratory conditions. Further evaluation of residual aluminum, sludge characteristics, treatment costs, and performance in real wastewater is required to determine practical applicability and environmental performance.

Next MaterialsVol. 14
Mashhad University of Medical Sciences (IR)
Mashhad University of Medical Sciences
Clean water and sanitation, Responsible consumption and production
Coagulation and Flocculation Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon